Assembly of the Air Vents

See Figure 5.
For the 18" and 24" models, the air vent
is attached to the ¼" threaded nipple
which comes attached to the manual air
bleed assembly. The rest of the manual
air bleed assembly is not needed. This
¼" threaded nipple is then installed onto
the 6" closure on top of the filter.
For the 30" and 36" models, the air vent
adapter should first be installed on the
8" closure on top of the filter. The Air
Vent can then be threaded onto this
adapter. Note: This fitting is reverse
thread, so to tighten, twist the nut
counterclockwise.
There is a plastic air relief tube (item #9
on the Replacement Parts diagram of
the Filter Manual) inside the filter
attached to the Lower Piping Assembly;
it has a small screen filter on the upper
end. This tube is not attached to any
part of the external Air Vent structure.
The tube with the screen filter should be
placed inside the dome of the top cover
during final assembly.
NOTE: For all threaded connections, be
certain to use adequate amount of
Teflon tape or paste to create a good
seal.