OPERATING INSTRUCTIONS
4.11.2
Face plate assembly installation / Concrete-liner pool
fig. 23
Cut out the pool liner to fit. Remove the mounting protection film (C). Place the clamp
gasket (39.1) between the installation housing and the liner and screw the clamp ring (30)
to the installation housing using the screws (74). The sealing contact faces must be clean
and smooth. After connecting the air button, put on the face plate assembly (35), this allows
the pressure connection and air connection to slide into one another. Fasten to the clamp
ring (30) with the screws (90.2).
Warning!
Make sure that there is not a kink in the switching tube (21), lay it in a loop and
do not shorten!
4.11.3
Face plate assembly installation / Pre-fabricated pool
fig. 24
C2 rondo
Version: 27200 - D
C
10
21
30
35
39.1
74
90.2
8436
10
21
30
35
90.3
After connecting the air button, put on the
face plate assembly (35), this allows the
pressure connection and air connection
to slide into one another. Fasten to the
clamp ring (30) with the screws (90.3).
Warning!
8437
Make sure that there is not a kink in the
switching tube (21), lay it in a loop and do
not shorten!
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
Mounting protection film
Suction housing
Switching tube
Clamp ring
Face plate assembly
Clamp gasket
Screw
Screw
Suction housing
Switching tube
Clamp ring
Face plate assembly
Screw