LumaPro 2LBL3 Manual De Instrucciones página 4

Detector de movimiento y control de luz
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
before it will detect motion. When first turned
on, wait 1
/
minutes.
1
2
❒ Turn the RANGE control to the medium position
(halfway between MIN and MAX), D
and the ON-TIME control to the TEST position.
MAX
ON-TIME
MIN
TEST 1 5 20
RANGE
MINUTES
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
15 ft.
(4.6 m)
70 ft.
D
Z
ual
one
(21 m) (30.5 m)
Maximum Range
/
minute warm up period
1
2
B
to OFF,
®
ual
rite
DUAL BRITE™
OFF 3 6 DUSK TO
HOUR
DAWN
D
Z
ual
one
100 ft.
Boosted
Maximum
Coverage Angle
NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
Motion
D
Z
ual
one
Least Sensitive
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several
times when motion is detect-
ed). Move the sensor head up,
down, or sideways to change
the coverage area. Keep the
sensor at least 2" (51 mm)
away from the lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head
by tightening the clamp
screw. Do not overtighten the
240°
screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
❒ Set the D
B
ual
dusk you want the lights on at low level (Off, 3, 6
Hrs., Dusk-to-Dawn).
WARNING - Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
NOTE: D
Z
ual
one
the motion sensor. D
adjustment and operates in conjuction with the for-
ward-looking sensor.
4
Motion
D
ual
Sensor
Most Sensitive
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
switch to the amount of time after
®
rite
™ adds a zone of detection under
Z
™ requires no additional
ual
one
Z
one
Clamp
Screw
Ball
Joint
598-1325-00

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para: