Descargar Imprimir esta página

Mode=2, Works Associated With Outdoor Station - ABB Welcome 83327-500 Manual Del Usuario

Ocultar thumbs Ver también para Welcome 83327-500:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 75
ABB-Welcome
4.2.2

Mode=2, works associated with outdoor station

Fig. 3:
Mode=2, works associated with outdoor station
Rotary
Value
Mode
2
Addr
1
ID
1
Dip Switch 1-4
Capacity
Each camera interface supports 4 analog cameras.
A total of 15 cameras can be associated with each outdoor station (including 2 built-in cameras in
outdoor station).
Operation
Press
to view the cameras individually during surveillance.
Pos : 74 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Bedienung/Master/Sl ave Schalter s etz en 83220-AP- xxx @ 19\mod_1310723320966_15.doc x @ 107833 @ @
|
Note
Camera interface work associated with outdoor station.
Address of the associated outdoor station, from 1-9.
ID can be set from 1-9, and should be unique.
Turn to ON when a camera is connected.
— 7 —