At low room temperatures, frost may buildup at the evaporator during
operation. The unit will automatically start defrosting and the POWER
LED blinking. The defrost control sequence is as follows:
A. When the unit operates in the cooling operation, drying operation, the
ambient temperature sensor senses the evaporator coil temperature is
below -1°C, after the compressor will stop operating for 10 minutes or
the coil temperature up to 7°C, the unit restart to cool operating mode.
5.4.10.
In the event of a power loss, to protect the compressor there is a 3
minute delay until the compressor restarting.

Overload Protection

62