3.-
OPERATION
PUESTA EN FUNCIONAMIENTO
Filling up.Open the shut-off valve once the immersion heater has been
installed.Open the hot water taps.Water appears as soon as the unit fills up
completely.Close the taps and check the system for leaks.
Do not connect the immersion heater to the mains until you are sure it is full.
Electric connection.Plug it into the mains and press the main power switch
to turn the appliance on.A light flashes when the heating element is working.
The thermostat re-activates the heating element after a certain amount of hot
water has been used.
Setting water temperatures.The dial on the thermostat can be used to
adjust the hot water temperature between approximately 30 ºC (minimum
position) and 75 ºC (maximum position).
E Position.(Energy saving).The water reaches a temperature of around 55
ºC.Heat losses are minimum in this position and the formation of lime
deposits are practically reduced.
It is recommended to have the water heater always plugged into the mains,
as the thermostat will only run the unit when necessary to keep the water at
the selected temperature. The polyurethane insulation foam means that any
heat loss will be insignificant.
Draining the unit.The heater should be drained if it is not to be used for
extended periods of time and if there is any risk of freezing pipes at the
premises where it is installed.The heater can be drained using the safety
valve.Always remember to:
- Unplug the unit.
- Close the water inflow valve.
- Open the hot water tap.
Unplug the water heater and contact the Technical Assistance Service is you
see any continuous steam or boiling water coming out of the drain or when
you open a tap.