3.9. SET PARAMETER
Press SET/0~9 key 3 seconds. L'écran montrera le menu. Now show menu. Press SET/0~9 sequentially it displays:
rAngE (set limit)
UnIt5 (choose unit)
A-OFF (choose auto power off)
FILt (display filter)
2ero (set auto
→ T
←)
bU22Er (set buzzer)
d (choose division)
d-dP (choose single or dual display)
3.9.1
Set range of auto-zero:
When it shows "rAngE", press
to confirm.
When choose "on" and press
once to increase the current digit, press
led "+" turns on, then you can config upper limit with the same procedure; when finishing auto exit and set "over" after setting into
weighing.
When low limit > high limit, it displays "oFF", then exit.
Caution: when the display is not stable, no led lights.
Alarming indicate: if bu22er parameter is set to on, alarm will sound if the weigh over the pan is on ok zone.
3.9.2
Change Unit
Cuando muestra "UnIt5", presione
salir.
Unidades: x9 (kg), pc5 (cuentapiezas),lb.lb (lb), Lb.o2 (lb.oz), 9 (g).
Cuentapiezas: cuando la pantalla muestra "pc5" presione
tra count y vuelve a 0. Entonces coloque la muestra y presione
que compone la muestra. Después de acabar muestra "pc5" y se enciende el led "
Para salir de la función cuentapiezas, elija una unidad.
Precaución: Coloque cantidades de como máximo 30000.
3.9.3
A-oFF (Choisir éteindre automatiquement)
When menu displays A-oFF, press
minutes in zero, auto-off.
3.9.4
Change display filter:
When it displays "FILtX" (FILt1 means one step change display, FILt2 means 3-4 steps change display, FILt3 means 6-8 steps chan-
ge display) Press SET/0~9 to change, press
3.9.5
Set range of auto-zero:
When it displays 2ero, press
division value when n=3000). Press SET/0~9 to choose and
3.9.6
bUZZEr (set buzze)
When menu displays bU22Er, press
3.9.7
Change division value
When menu displays d, press
14
→ T ←
and then SET/0~9 to choose "on" or "oFF", "on" is start the function, "oFF" is exit, press
→ T
←, now you will weigh with limit; led "-"(under limit) lighting, first digit is blinking, press SET/0~9
→ T ←
to confirm and edit next digit; once you finish to set all "-" digits, when you press
→ T
←, entonces presione SET/0~9 para elegir, entonces presione
→ T ←
to enter, press SET/0~9 to choose "n" o "y", "n" is not auto power off, "y" means, after 10
→ T ←
to confirm and exit.
→ T
←, now shows 2ero x.x (x.x is the range: 0.5d, 1d, 1.5d, 2d, 2.5d, 3d, 3.5d, 4d, 4.5d, 5d. "d" is the
→ T ←
to enter, press SET/0~9 to choose "on" or "oFF", press
→ T ←
to enter, press SET/0~9 to choose division.
→ T
←. Ahora se enciende el led
→ T
←. Presione SET/0~9 y
".
→ T ←
to confirm.
USER'S MANUAL SS
→ T ←
para confirmar y
. Presione largamente
ON/→ 0
→ T ←
para introducir la cantidad de piezas
→ T ←
to confirm.
EN
→ T ←
→ T
←,
←, mues-