General informations

>3°
9.
Mounting
BMMS K
M4 DIN912 (3x)
max. 2.5 Nm
2.
1.
Fit cable transducer on a plain base to avoid excessive force on housing. Make sure that drainage holes are free. It is
recommended to use flat washers.
>3°
BMMS M
M6 DIN912 (3x)
max. 2.5 Nm
2.
1.
Protect cable transducer and measuring wire as far as
possible from water. Avoid mounting with measuring wire
outlet pointing upwards (especially in outdoor applications)
to reduce risk of water entry. Freezing water can lead to
damage. Drainage holes can be opened to allow water
to drain. Prefer mounting cable transducer with drainage
holes in low position.
Ensure pulling out of measuring wire in straight direction.
Maximum misalignment ≤3°. Use pulley to limit misalign-
ment. Do not loop measuring wire around objects or allow
them to touch measuring wire. Protect measuring wire
from dirt and damage.
<3°
Ensure free rotation of measuring wire fixation to assure
optimum wire guiding.
Letting snap back of pulled out measuring wire can cause
injuries and damage of cable transducer.
10. Teach process
Activate teach process
Set "Set-input" on HIGH for 6 seconds and afterwards on
LOW level.
DV/Status output: Oscillates after 5 seconds.
Position 1
Get cable transducer on position 1 intended for voltage
output 1 / current output 1. Set "Set-input" for 1 second on
HIGH level.
DV/Status output: Switches to HIGH level for 3 seconds
and flashes shortly.
Position 2
Get cable transducer on position 2 intended for voltage
output 2/current output 2. Set "Set-input" for 1 second on
HIGH level.
DV/Status output: Switches to LOW level for 3 seconds
and oscillates afterwards.
If measuring range is exceeded or the limits are too close
to each other, the teaching process was not successful and
has to be repeated.
Set / restore default
Set „Set-input" for 16 seconds to HIGH. DV/Status output:
Oscillates after 5 seconds. Note: The cable transducer hast
to be completely drawn in.
Behavior
U
Pos 2
Pos 2
Pos 1
Pos 1
Teach in direction - move in
Teach in direction - move out
11. Disposal
The cable transducer contains electronic components.
At its disposal, local environmental guidelines must be
followed.