Victron energy BlueSolar PWM 48V Manual Del Usuario página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
4. SETTING THE LOAD OUTPUT
4.1 Settings
0
Load output permanently off
Load output turned on during
1
1 hour after sunset
Load output turned on during
2
2 hours after sunset
Load output turned on during
3
3 hours after sunset
Load output turned on during
4
4 hours after sunset
Load output turned on during
5
5 hour after sunset
Load output turned on during
6
6 hours after sunset
Load output turned on during
7
7 hours after sunset
Load output turned on during
8
8 hours after sunset
Load output turned on during
9
9 hours after sunset
Load output turned on during
0.
10 hours after sunset
Load output turned on during
1.
11 hours after sunset
Load output turned on during
2.
12 hours after sunset
Load output turned on during
3.
13 hours after sunset
H
Manual load control
Load output controlled by
C
battery voltage only
L
Dusk to dawn mode
d
Debug mode
3

Publicidad

Tabla de contenido
loading

Tabla de contenido