Operation / Cleaning, maintenance, storage, transport and ordering of spare parts
Starting the engine
IMPortAnt!
When starting with the reserve starter
may recoil suddenly as it starts up, resulting in hand
injuries.
Wear protective gloves when starting
the equipment.
O pen the petrol cock
S et the ON / OFF switch
position.
M ove the choke lever
S tart the engine with the reversing starter
by pulling forcefully on the handle. If the engine
does not start, pull the handle again.
P ush the choke lever
11
has started.
Connecting consumers
to the generator
C onnect the equipment you want to use to the
230 V ~ sockets
.
3
IMPortAnt! These sockets may be loaded
continuously (S1) with 2600 W and temporarily
(S2) for a maximum of 2 minutes with 2800 W.
J
T he generator is suitable for 230 V ~ AC appli-
ances only.
D o not connect the generator to the household
mains system as this may result in damage to
the generator itself or to other electrical appli-
ances in your home.
note: Some electrical appliances (power jigsaws,
drills, etc.) may have a higher level of power con-
sumption when used in difficult conditions
Switching off the engine
B efore you switch off the generator, allow it to
run briefly with no consumers so that it can
"cool down".
46 GB/MT
, the motor
12
by turning it down.
13
to the "ON"
10
to position I Ø I.
11
,
12
back after the engine
S et the ON / OFF switch
position.
C lose the petrol cock
13
overload cut-out 2 x 230 V
socket-outlets
IMPortAnt! the generator is fitted
with an overload cut-out.
This shuts down the sockets
sockets
by pressing the overload cut-out
3
IMPortAnt! If this happens, reduce
the electric power you are taking from
the generator or remove any defective
connected appliances.
IMPortAnt! Defective overload cut-
outs must be replaced only by overload
cut-outs of identical design and with the
same performance data. If repairs are
necessary, please contact your customer
service center.
Cleaning, maintenance,
storage, transport and
ordering of spare parts
Switch off the motor and pull the spark plug boot
from the spark plug before doing any cleaning and
maintenance work on the equipment.
AttEntIon! Stop the appliance in-
stantly and contact your point of service:
–
I n the event of unusual vibrations or noise
–
I f the engine appears to be overloaded or
misfires
Cleaning
K eep all safety devices, air vents (Fig. A/Item
A1) and the motor housing free of dirt and
dust as far as possible. Wipe the equipment
to the "OFF"
10
.
. You can restart the
3
.
5