NOVASTAT RF MINI (RT-RFK) - USER GUIDE
1 channel RF Receiver 230Vac for RF thermostats RF Basic, RF
Digital, RF Week.
MODES DESCRIPTION
-
Radio frequency RF receiver (868 MHz) for water floor heating
systems controlled by actuators.
-
Personal code, thus a clear allocation to the thermostat is ensured.
-
Equipped with a push button to select AUTO, MANUAL or RF INIT
mode.
-
To be used only with ours RF thermostats RF Basic, RF Digital, RF
Week
Mode push button
AUTO Mode
Press button
Manual Mode
(Heater forced)
Press button
Manual Mode
(Stop forced)
Press button
during 4sec
Press button
RF init
Press button
RF LED.
Manual Mode LED.
(Green)
(Yellow)
Heating LED.
(Red)
RADIO CONFIGURATION MODE
1. Install and plug the receiver. Then press the receiver push button during 4
seconds, the Green LED should lit up indicating that the receiver is now in radio
configuration mode (RF INIT) waiting for a thermostat configuration address.
2. Please refer to the thermostat leaflet for enter the thermostat in "RF Init" mode.
3. Verify that radio signals are correctly received by the receiver. On the receiver, the
Green LED should blink at each radio signal received from the thermostat.
4. Exit the radio configuration mode on the thermostat. (Please refer to the thermostat
leaflet)
5. Now starting up your installation in AUTO mode.
LED INDICATOR
Yellow
Red
Green
0
0
0
Automatic mode, HEATER stopped
0
1
0
Automatic mode,
1
0
0
Manual
1
1
0
Manuel
quick flash
0 or
1
0 or
1
Waiting for initialization
0 or
1
0 or
1
1
Waiting for a
slow blink
0
0
ERROR see repair sequence bellow:
- Verify the emitter batteries.
- Verify the emitter/receiver range.
- No perturbation by an apparatus at less than 50cm of
Repair instructions
the receiver.
- No perturbation by an apparatus on the 868 MHz
frequency (continuous transmission).
By pressing on the push
- Verify that the receiver is correctly connected
button
- Verify main power supply (230VAC)
nothing happens
TECHNICAL CHARACTERISTICS
0°C - 50°C (32°F – 122°F)
Operating temperature
Electrical
Class II - IP44
Protection
Power Supply
230Vac 50Hz
868 MHz, <10mW.
Radio frequency and
Range of approximately 100m in open space.
Receiving zone
Range of approximately 30m in residential environment.
CE. EN 300220-1, EN 301489-1
certifications
(Radio frequency certifications)
Output
Relay 12A 250Vac
HEATER operating
mode OFF forced
mode
HEATER forced
configuration
signal (cf. configuration)
GB