TIG cold-wire feeder
6.6 Connecting the shielding gas
Fig. 20 Overview of connections and control elements on page EN-26
NOTICE
• The valve of the shielding gas cylinder must be closed when the gas hose is installed.
• To ensure a tight connection between the shielding gas hose and the connector, the nut must be
1 Connect the shielding gas hose to the gas connector (13).
2 Connect the shielding gas hose to the shielding gas cylinder.
6.7 Connecting the torch cable assembly
NOTICE
• Only use intermediate cable assemblies and torch cable assemblies designed for the ABIDRIVE V2.
• Applies to liquid-cooled welding torches only.
• Please also consult the operating instructions for the welding components, such as welding torch and
• Ensure that the coolant supply and return hoses have been correctly installed.
• Do not use deionised or demineralised water as coolant or for leak and flow tests. This may shorten
• Only use special welding coolant.
• We recommend using ABICOR BINZEL BTC coolant.
• The use of unsuitable coolants may damage the system and void the warranty.
1
2
Fig. 15
1 Connect the coolant supply (5) and coolant return (6) to the ABIDRIVE (1).
tightened completely using a spanner.
power source.
Coolant supply = blue, coolant return = red.
your welding torch's service life.
1
6
ABIDRIVE V2
Welding torch with cable assembly
Connecting the coolant
5
4
3
Central connector
5
Cable assembly coolant supply
4
6
Control lead connector
Cable assembly coolant return
6 Putting into operation
2
3
EN - 21