2.6.5 Menú de Configuración del Modelo 700 – En la Pantalla del Transmisor
Home Screen
Main Menu
Device Setup
Quick Start
Identity
Basic Config
I/O Config
Display Config
Advanced Config
Factory Config
Home Screen
Main Menu
Device Setup
Quick Start
Identity
Basic Config
I/O Config
Display Config
Advanced Config
Factory Config
SP57-660 Eclipse Modelo 700 Transmisor Radar de Onda Guiada
Product Name
(read only)
Magnetrol S/N
(read only)
Hardware Version
(read only)
Firmware Version
(read only)
LongTag
Measurement Type:
Level Only
Interface and Level
Interface and Volume
Volume and Level
Flow
Level Units:
Inches
Feet
Millimeters
Centimeters
Meters
Probe Model:
7zF Sngl Rod Tanks
7zP Coax HP
7zT Coax Std
7z1 Sngl Flex Std
Probe Mount:
NPT
BSP
Flange
Probe Length:
12 inches to 100 feet
(30 cm to 30 m)
Level Units:
Inches
Feet
Millimeters
Centimeters
Meters
Probe Model:
7zF Sngl Rod Tanks
7zP Coax HP
7zT Coax Std
7z1 Sngl Flex Std
Probe Coating: (7zF only)
None (Bare)
PFA Coated
Probe Mount:
NPT
BSP
Flange
Level Offset:
-25 feet to +75 feet
(-7.6 m to 22.9 m)
Dielectric Range:
Below 1.7
1.7 to 3.0
3.0 to 10
Above 10
4 mA Set Point (LRV):
-25 feet to +175 feet
(-7.6 m to 53 m)
20 mA Set Point (URV):
-25 feet to +175 feet
(-7.6 m to 53 m)
Failure Alarm:
22 mA
3.6 mA
Hold
Probe Length:
12 inches to 100 feet
(30 cm to 30 m)
Level Offset:
-25 feet to +75 feet
(-7.6 m to 22.9 m)
Dielectric Range:
Below 1.7
1.7 to 3.0
3.0 to 10
Above 10
25