Wireless Device Setup and Programming
[804][000] Enroll Wireless Devices
1. Enter Installer Programming section [804][000].
2. When prompted, either activate the device (see device installation sheet) to enroll immediately or enter
a device ID number. Do the latter to pre-enroll devices then enroll them later at the customer site.
The alarm panel determines the type of device being enrolled and presents the appropriate
programming options.
3. Use the scroll keys or type in the corresponding number to select an option.
4. Scroll through the available selections, key in a number or enter text as appropriate.
5. Press [*] to accept and move to the next option.
6. Once all options are configured, the system prompts to enroll the next device.
7. Repeat the process described above until all wireless devices are enrolled.
[804][001]-[716] Wireless Device Configuration
To configure wireless devices:
1. Enter Installer Programming section [804] then select one of the following sub-sections:
• 001-128 – Configure wireless zones
• 551-556 – Configure wireless sirens
• 601-632 – Configure wireless keys
• 701-716 – Configure wireless keypads
2. Select a device to configure using the scroll keys or go directly to a specific device by entering a
hotkey.
3. Use the scroll buttons or enter a hotkey to select a configuration option for the device. See device
sheets for details.
4. Press [*] to accept and move to the next option.
5. Once all options are configured, the system returns to the base configuration menu.
Repeat the process described above to configure other wireless devices.
[804][801] RF Jam Detect
To configure RF jamming:
1. Enter Installer Programming section [804][801].
Select one of the following options by scrolling or entering the hotkey:
• 00 – Enabled/Disabled
• 01 – UL 20/20-USA
• 02 – EN 30/60-Europe
• 03 – Class 6 30/60-British
2. Press [*] to accept the selection.
3. Press [#] to exit the section.
[804][802] Wireless Supervision Window
For EN installations, 1 hour or 2 hours must be selected.When option 06 is used, which configures
the system to generate fault conditions after a device has been detected as absent for 24 hours, smoke
detectors generate a fault condition after a maximum of 18 hours when the supervision toggle option
is disabled.
To program the Wireless Supervisory Window:
1. Enter Installer Programming section [804][802].
2. Select one of the following options by scrolling or entering the hotkey:
• 00 – Enabled/Disabled
6