12. ELECTRICITY CONNECTION
The device must definitely be connected to a source of energy with earth.
The device should be connected to a mono-phase grounded electrical line of 220 - 230 V
with 2 A. V-Automatic fuse.
13. CIRCUIT DIGARAM AND ROOM THERMOSTAT
For the Room Thermostat connection, the short circuit connection shown in Figure.12
is removed on the board and is being replaced by a room thermostat connection cables.
Simple types and digital type room thermostats can be connected via this connection.
·
º
Please contact the authorized service center for the room thermostat connections that
have the properties of operating ali the functions of the device, including domestic water.
You can be connected to the internet and remate access can be provided through the room
thermostats having these properties. You can also control the device through mobile
phones and tablets as well that provide the necessary features when needed.
Figure.12
27
Room
Thermostat
Connection