4
70
man_PGC 3009 ('20) V5.indd 70
man_PGC 3009 ('20) V5.indd 70
Note:
1.
If a new tank has just been connected, please allow at least one minute or
more for the air in the gas pipeline to purge out through the pilot hole,
2.
If the pilot light has not ignited, turn heater control knob to OFF position,
fully close gas valve, wait 5 minutes, then repeat steps 1-7 of the Lighting
Instructions.
If the burner flame goes out accidentally or it is blown out by wind, turn off
the heater and wait at Ieast 5 minutes or more to let the gas dissipate before
re-lighting to avoid possible gas explosion. Repeat steps 1 to 7.
ES
FR
Apagado
Off
Posición
Position
de encen-
d'allumage
dido
LOW
Capacidad
Capacité
baja
faible
HIGH
Alta capa-
Capacité
cidad
élevée
Table 1
TO TURN OFF THE HEATER
a)
Fully close the gas valve of the regulator or the gas valve at the gas bottle.
b)
Turn control knob clockwise from "PILOT" to "OFF": press knob B in oder to
be able to turn to "OFF".
WARNINGS
•
The whole gas system. hose, regulator, pilot and burner should be inspected
for Ieak before use. But at least once a month and each time the gas cylinder
is changed. Check the hose assembly for sign of extreme abrasion, cuts or
wears. Suspected areas should be Ieak tested. If the hose Ieaks, it must be
replaced with a new one that conforms to IocaI standard codes. ). If it shows
signs of cracking, splitting or other deterioration it shall be exchanged for
new hose of the same length and of the equivalent quality.
•
Make sure the ventilation opening of the cylinder enclosure, controI com-
partment, burner and circulation air passageways of the heater are free and
clear of debris. If debris, spider or insect nests are found, clean the holes with
heavyduty pipe cleaner or compressed air.
•
Always keep a dry chemical fire extinguisher readily available.
•
For safety, always allow a 5-minute complete shut off period before re-light-
ing a hot heater.
•
Replace the gas tube/hose within the interval described with the hose.
REPLACING THE GAS CYLINDER
•
Shut off heater.
•
Fully close the gas valve of the regulator or the gas valve at the gas bottle.
•
Disconnect the regulator from the cylinder following the instructions that
came with your regulator.
•
Replace the cylinder.
•
Make sure there is no flame. Only when no flame: remove the plug or seal
cap from the cylinder valve.
GB
IT
NL
Off
Spenta
Uit
Ignite posi-
Posizione
Ontstekings
tion
di accen-
positie
sione
Low capac-
Bassa capa-
Laag ver-
ity
cità
mogen
High
Alta capa-
Hoog ver-
capacity
cità
mogen
SLO
PT
Off
Off
(Desligado)
Posição
Vžgite
para acen-
položaj
der
Baixa capa-
Nizka
cidade
kapaciteta
Elevada
Velika
capacidade
kapaciteta
19-11-20 14:46
19-11-20 14:46