Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 48
Production date:
Production code sticker filter cartridge and packaging - Example: B715002010
7
Production year, here: 2007
15
Production week, here: calendar week 15
002
Batch No. filter medium, here the second batch filled in terms of quantity
010
Serial number of the filter cartridge, here the tenth cartridge from the second batch
Production code sticker connector head - Example: 7102 XX
7
Production year, here: 2007
10
Production week, here: calendar week 10
2
Production day from Monday (1) to Friday (5), here: Tuesday
xx
Internal code
Production date pressure vessel and pressure vessel lid - Example: 0307
03
Production month, here: March
07
Production year, here: 2007
3.5 Technical Safety Assembly Instructions
The terminal device operated with the filter must be free of limescale prior to
installation.
!
the filter system.
Protect the filter system from sunlight and mechanical damage. Do not assemble
near sources of heat and open flames.
A stop valve must be installed before the filter system intake hose.
If the water pressure is higher than 6 bar, a pressure reducer must be installed before
the filter system.
A non-return valve tested by the DVGW has been factory-installed at the water intake
of the filter head.
No copper pipes and no galvanised or nickel-plated pipes/connectors may be
installed between the water filter and the consumer. When choosing the material for
parts that come into contact with water after the HYDROS filter system it must be
remembered that, due to the process, decarbonised and/or fully demineralised water
contains free carbon dioxide. The use of the HYDROS hose sets is recommended.
All parts must be installed in accordance with the country-specific guidelines on the
installation of water facilities.
4 Installation
Caution: Prior to installation read the technical data (Chapter 10) and the operating
!
and safety information (Chapter 3). After the product has been stored at temperatures
below 0 °C, it must be stored (with the original packaging open) at the ambient
temperature of the place of installation for at least 24 hours before use.

4.1 Scope of Delivery

Prior to installation, remove the entire delivery scope from the packaging and
check that everything is there:
1x pressure vessel
1x pressure vessel lid
1x filter cartridge
2
1x manual
Caution: No water softening system may be operated upstream from
1
3
13

Publicidad

Tabla de contenido
loading

Tabla de contenido