Descargar Imprimir esta página
LEGRAND Pass & Seymour 1594-PC2A Instrucciones De Instalación Y  Operación
LEGRAND Pass & Seymour 1594-PC2A Instrucciones De Instalación Y  Operación

LEGRAND Pass & Seymour 1594-PC2A Instrucciones De Instalación Y Operación

Portable ground fault circuit interrupter (gfci)

Publicidad

Enlaces rápidos

INSTALLATION AND
OPERATING
INSTRUCTIONS
PORTABLE
GROUND FAULT CIRCUIT
INTERRUPTER (GFCI)
Pass & Seymour/Legrand's portable ground fault circuit interrupter (GFCI) provides per-
GENERAL
sonnel ground fault protection. Conventional over-current protection devices such as
fuses and circuit breakers cannot protect people from electrical shock. Those devices
are designed to disconnect the power when currents of several amperes flow from the
hot wire to ground. However, currents as low as a few milliamperes can be dangerous
to normal healthy human beings. One ampere equals 1000 milliamperes.
Many electrical shocks occur when the path of current flow is from the hot wire through
the metal housing of a defective tool or appliance, through the body of a human being
to ground. Because of the resistance of the human body to electrical current flow, the
current will be quite low relative to that required to cause conventional over-current pro-
tection devices to function. However, it is likely to be high enough to cause a painful or
possibly lethal electric shock to a human being.
Pass & Seymour/Legrand's portable GFCI is designed to remove power from the
equipment loads when these loads have a potentially lethal ground current in excess of
six milliamperes. Normal loads will draw current from the Hot Conductor (black wire)
and return it to the power source through the Neutral Conductor (white wire). Faulty
loads can return some of the current to the power source through a ground path such
as a water pipe, gas pipe, wet floor, third conductor (green wire), or worst of all, through
a person who is in contact with an extrinsic ground.
The Pass & Seymour/Legrand portable GFCI's rugged construction allows it to be used
in outdoor or indoor locations, where ground fault protection is desired. When ener-
gized by actuation of the reset button, it will conveniently supply power to any power
tool or appliance whose load requirement does not exceed rated voltage and currents.
1. Plug unit into 120 VAC power socket protected by fuse or circuit breaker.
INSTALLATION AND OPERATION – MANUAL RESET VERSION
2. Press and release "Reset" button.
3. Verify the lamp indicator is lit (this step denotes that power is on).
4. Press "Test" button.
5. Verify the lamp indicator turns off (this step denotes that the power is off).
6. Press and release "Reset" button for use.
7. Connect the desired load equipment to cord output receptacle and operate
equipment normally.
1. Plug unit into 120 VAC power socket protected by fuse or circuit breaker.
INSTALLATION AND OPERATION – AUTO RESET VERSION
2. Unit will automatically become energized and red lamp indicator must be lit
3. Press "Test" button.
4. Verify the lamp indicator turns off (this step denotes that the power is off).
5. Press and release "Reset" button for use.
6. Connect the desired load equipment to cord output receptacle and operate equip-
ment normally.
1. If the GFCI fails to trip when the Test button is pressed (lamp indicator fails to turn
WARNINGS
off) or, if the GFCI fails to reset when the Reset button is pushed in (lamp indicator
fails to remain lit), the device should be replaced.
2. If the GFCI tests properly without any appliance plugged into it but trips each time
the appliance is plugged in, the appliance has a ground fault and needs to be
repaired or replaced. DO NOT BYPASS THE GFCI. IF THIS CONDITION OCCURS,
A REAL SHOCK HAZARD MAY EXIST.
Note 1: Pass & Seymour/Legrand's portable power plug models will provide protection
NOTES
against ground faults when used with a 2-wire outlet receptacle and a 3-wire to 2-wire
adapter. It is always desirable when possible to use a 3-wire grounded receptacle
because a ground provides additional protection against electrical shock hazard. The
adapter should be of the type that can be grounded to the outer mounting plate screw.
Note 2: The GFCI does not sense ground faults in the input conductors, therefore it is
recommended that if any extension cords are used, they should be connected between
the GFCI's output and the tool or appliance to be powered. Your GFCI is now ready to
test and use.
1. Do not connect any electrical cord longer than 250 feet to the GFCI output
CAUTIONS
receptacle in order to avoid possibility of nuisance tripping.
2. This GFCI device is to be used on 120V/60Hz circuit only (such as normal house-
hold electrical distribution system).
3. Ground fault circuit interrupters, whether this device or any other, cannot protect
against electrical shock resulting from contact with both hot and neutral wires of the
electrical circuit nor against defects in any wiring supplying the device.
4. DO NOT USE IF THE BUTTON BOOTS OR CASE OR CORD HAVE BEEN
5. Test frequently and at least before each use of load equipment to insure correct
DAMAGED.
operation.
6. The GFCI is designed as a protective device. Do not use as an off/on switch.
7. Do not use on circuit with life support apparatus.
Pass & Seymour/Legrand will remedy any defect in workmanship or material in Pass &
LIMITED ONE YEAR WARRANTY
Seymour/Legrand products which may develop under proper and normal use within
one year from the date of purchase by a consumer. (1) by repair or replacement, or at
Pass & Seymour/Legrand's option, (2) by return of the amount equal to the consumer's
purchase price. Such remedy is IN LIEU OF ANY AND ALL EXPRESSED OR IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PUR-
POSE. Such remedy by Pass & Seymour/Legrand does not include or cover cost of
labor for removal or reinstallation of the product. ALL OTHER FURTHER ELEMENTS
OF DAMAGE (INCIDENTAL OR CONSEQUENTIAL DAMAGES) FOR BREACH OF
ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES INCLUDING WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE
EXCLUDED HEREBY. (Some states do not allow disclaimer or exclusion or limitation of
incidental or consequential damages, so the above disclaimers and limitation or exclu-
sion may not apply to you.) ANY IMPLIED WARRANTIES INCLUDING WHERE
REQUIRED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICU-
LAR PURPOSE SHALL BE LIMITED TO THE ONE YEAR PERIOD SET FORTH
MODEL NUMBERS
AUTO-
MANUAL
15 Amp
1594-PC2A
1594-PC2M
RESET
RESET
1594-PC6M
1594-TL2A
1594-TL2M
1594-TC2A
1594-TC2M
20 Amp
2094-PC2A
2094-PC2M
2094-TL2A
2094-TL2M
ABOVE. (Some states do not allow limitation on how long an implied warranty lasts, so
the above limitation may not apply to you.)
To ensure safety, all repairs to Pass & Seymour/Legrand products must be made by
Pass & Seymour/Legrand or under its specific direction. Procedure to obtain perfor-
mance of any warranty obligation is as follows: (1) Contact Pass & Seymour/Legrand,
P.O. Box 4822, Syracuse, NY 13221 for instructions concerning return or repair; (2)
return the product to Pass & Seymour/Legrand, postage paid, with your name and
address and a written description of the installation or use of the Pass &
Seymour/Legrand product, and the observed defects or failure to operate, or other
claimed basis for dissatisfaction.
This warranty gives you specific legal rights and you may also have other rights which
vary from state to state.
INSTRUCCIONES DE
INSTALACIÓN Y
OPERACIÓN
INTERRUPTOR DE
CIRCUITO ACCIONADO POR
CORRIENTE DE PÉRDIDA
A TIERRA (GFCI) PORTÁTIL
Los interruptores de circuito accionado por corriente de pérdida a tierra (GFCI)
GENERAL
portátiles de Pass & Seymour/Legrand protegen las personas contra las fallas
a tierra. Los dispositivos convencionales de protección contra la sobrecorrientes tales
como fusibles y disyuntores no pueden proteger a las personas contra los choques
eléctricos. Estos dispositivos están diseñados para desconectar el suministro eléctrico
cuando corrientes de varios amperios fluyen del cable cargado a tierra. Sin embargo,
corrientes de sólo unos pocos miliamperios pueden ser peligrosas para personas
normales y saludables. Un amperio es igual a 1000 miliamperios.
Muchos choques eléctricos ocurren cuando la corriente pasa desde el alambre
cargado a través de la caja metálica de una herramienta o aparato defectuoso y a
través del cuerpo de una persona a tierra. Dada la resistencia del cuerpo humano al
flujo de corriente eléctrica, la corriente será mucho mas baja que la corriente necesaria
para activar un dispositivo de protección contra sobrecorrientes convencional. Sin
embargo, es posible que sea lo suficientemente alta para causar un choque eléctrico
doloroso o mortal.
Los GFCI portátiles de Pass & Seymour/Legrand están diseñados para desconectar
el suministro eléctrico del equipo cuando este equipo tiene una corriente a tierra
posiblemente mortal de más de seis miliamperios. Las cargas normales consumen
corriente del conductor cargado (cable negro) y la envían de regreso mediante el
conductor neutral (cable blanco) hasta la fuente eléctrica. El equipo defectuoso puede
retornar parte de la corriente a la fuente eléctrica a través de una trayectoria a tierra
como sería una tubería de agua, una tubería de gas, el piso mojado, un tercer
conductor (cable verde) o, lo que es peor, a través de una persona que está en
contacto con una tierra extrínseca.
La robusta construcción de los GFCI portátiles de Pass & Seymour/Legrand permite
que se puedan utilizar en áreas exteriores o interiores donde se requiera protección
contra fallas a tierra. Cuando sea energizado mediante el accionamiento del botón
de reposición (RESET), convenientemente proveerá corriente a cualquier herramienta
o aparato eléctrico cuyos requerimientos de carga no sobrepasen las corrientes y
voltajes nominales.
1. Enchufe la unidad a un receptáculo de 120 VCA protegido por un fusible
INSTALACIÓN Y OPERACIÓN – VERSIÓN DE REPOSICIÓN MANUAL
o disyuntor.
2. Oprima y suelte el botón "RESET".
3. Verifique que la luz indicadora esté encendida (este paso indica que se está
suministrando energía eléctrica).
4. Oprima el botón "TEST" (prueba).
5. Verifique que la luz roja indicadora se apague (este paso indica que no se está
suministrando energía eléctrica).
6. Oprima y suelte el botón "RESET" para poder utilizar.
7. Conecte el equipo al receptáculo de salida del cable y opere el equipo
normalmente.
1. Enchufe la unidad a un receptáculo de 120 VCA protegido por un fusible
INSTALACIÓN Y OPERACIÓN – VERSIÓN DE REPOSICIÓN AUTOMÁTICA
o disyuntor.
2. La unidad se energizará automáticamente y deberá encenderse la luz roja
indicadora.
3. Oprima el botón "TEST".
4. Verifique que la luz roja indicadora se apague (este paso indica que no se está
suministrando energía eléctrica).
5. Oprima y suelte el botón "RESET" para poder utilizar.
6. Conecte el equipo al receptáculo de salida del cable y opere el equipo
normalmente.
1. Si el GFCI no se dispara cuando se oprime el botón "TEST" (la lámpara indicadora
ADVERTENCIAS
no se apaga) o si el GFCI no se reposiciona cuando se oprime el botón "RESET"
(la lámpara indicadora no se queda encendida), la unidad debe ser reemplazada.
2. Si el GFCI se prueba y funciona correctamente sin ningún aparato conectado pero
se dispara cada vez que un aparato se conecta, el aparato tiene una falla a tierra
y necesita ser reparado o reemplazado. NO PASE POR ALTO EL GFCI.
SI ESTA CONDICIÓN OCURRE, EXISTE UN PELIGRO REAL DE CHOQUES
ELÉCTRICOS.
Nota 1: Los modelos de enchufe de alimentación portátiles Pass & Seymour/Legrand
NOTAS
proveen protección contra fallas de tierra cuando se utilizan con un receptáculo de
salida de 2 cables y un adaptador de 3 cables a 2 cables. Siempre será mejor, si es
posible, utilizar un receptáculo de 3 cables con tierra porque la tierra provee protección
adicional contra los peligros de choques eléctricos. El adaptador debe ser del tipo
que se puede conectar a tierra mediante el tornillo de la placa de montaje exterior.
Nota 2: El GFCI no detecta fallas a tierra en los conductores de entrada. Por lo
tanto se recomienda que si se utiliza un cable de extensión, que sea conectado
entre la salida del GFCI y la herramienta o aparato eléctrico a energizar. Su GFCI
ahora está listo para probar y utilizar.
NÚMEROS DE MODELOS
REPOS.
REPOS.
15 Amp.
1594-PC2A
1594-PC2M
AUTO.
MANUAL
1594-PC6M
1594-TL2A
1594-TL2M
1594-TC2A
1594-TC2M
20 Amp.
2094-PC2A
2094-PC2M
2094-TL2A
2094-TL2M

Publicidad

loading

Resumen de contenidos para LEGRAND Pass & Seymour 1594-PC2A

  • Página 1 ABOVE. (Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.) INSTALLATION AND MODEL NUMBERS To ensure safety, all repairs to Pass & Seymour/Legrand products must be made by OPERATING AUTO- MANUAL Pass &...
  • Página 2 INSTRUCTIONS Pass & Seymour/Legrand remédiera à tout vice de matière ou d’exécution susceptible GARANTIE LIMITÉE D’UN AN NUMÉRO DE MODÈLE de se présenter dans les produits Pass & Seymour/Legrand dans le cadre de leur D’INSTALLATION ET RÉARM. RÉARM. utilisation correcte et normale pendant une période d’un an à compter de leur date 15 amp.

Este manual también es adecuado para:

Pass & seymour 1594-pc2mPass & seymour 1594-pc6Pass & seymour 1594-tl2aPass & seymour 1594-tc2aPass & seymour 2094-pc2aPass & seymour 1594-tl2m ... Mostrar todo