Figure 8: Unit backside: batteries compartment, tamper and DIP switch
configure
To
the DIP switch:
NOTE:
Configuring the DIP switches should be performed without the batteries connected.
1.
[For one-way operating mode]: Set the DIP switch 1 to 1-way, and configure either
smoke (2), heat (3) or smoke and heat.
NOTE:
Changing the DIP switch Smoke (2) to off will cause that Smoke Detector will not comply to
EN14604.
2. [For two-way operating mode]: Set the DIP switch 1 to 2-way, and configure activation
of the Smoke and Heat detectors from the system panel. (In this mode, the DIP switch
2 & 3 settings are irrelevant.)
3. Set the alarm system to registration mode.
a. Go to the main menu and select [9]>[1]>[1] (Programming > Devices > Zones)
b. Select a zone and press '√'
4. Open the battery compartment cover (see Figure 8).
WARNING:
The detector batteries are supplied inside of the unit, which are covered with
plastic wrapping. Remove the plastic wrapping from the batteries before
installation, and then perform a functional test of the detector according to the
Testing section of these instructions.
5. Remove the battery from the insulation material and reinsert it into the transmitter,
paying attention to the polarity.
6. Close the compartment cover.The detector will send a transmission. If the transmission
is successfully received by the system it will play a confirmation sound. If no
confirmation sound is heard send another transmission by pressing and releasing the
tamper switch of the device.
7. After the detector is successfully registered the display shows: Save? Press √ to
confirm and continue entering other parameters for the chosen device.
WARNING:
This detector is not suitable for installation in a hazardous location, as defined in the national
electrical code. Do not use detector in an outlet controlled by a wall switch.
8
* = DIP Switch default settings.
1 & 2-Way Smoke & Heat Detector
DIP Switch
Tamper
1-1-Way / 2-Way*
2-Smoke On / Off*
3-Heat Off / On*
*=Default