WIRING
LAN
IP LEN
GTH
STR
m
11m
1.2
0.65
〜
IP video intercom adaptor
JKW-IP
Cat5e/6
Straight-through cable
LAN
2C
Sensor
S1
input 1
E
NP
2C
Sensor
S2
input 2
E
NP
2C
Sensor
S3
input 3
E
NP
2C
Sensor
S4
input 4
E
NP
2C
Option
RY
output
RY
NP
2C
B1
B2
NP
2C
+
DC18V
-
P
SETTING UP
First, install the supplied software onto your PC in order to set up and use this unit.
Follow the operation manual located in each language folder of the accompanying CD-ROM to install and
set up the software.
OPERATION MANUAL &
Software (CD-ROM)
Switch (HUB)
To router
Option unit *1
Option unit *1
Option unit *1
Option unit *1
Option unit *2
J K m a s t e r
B1
monitor station
B2
+
Power supply
-
NP : Non-polarized
P : Polarized
de : German
en : English
es : Spanish
• Do not use the unmarked terminals for other purposes.
• For the connection of products manufactured by other
companies, refer to the manuals which accompany
them.
*1. Input specifications
Input method
N/O or N/C dry closure contact (start
signal only detection method)
Detection
100 mS or more
confirmation time
Contact resistance
During N/O dry closure: Less than 700 Ω
During N/C dry closure: At least 3 k Ω
Terminal short current Less than 10 mA
Voltage between
Less than 20 V DC(when open between
terminals
terminals)
*2. Output specifications
Output method
N/O dry closure contact
Voltage between
24V AC, 0.5A (resistive load)
terminals
24V DC, 0.5A (resistive load)
Minimum overload: 100mV DC, 0.1mA
PS-1820
18V DC 2A
100V - 240V- 50/60 Hz
Connection of stranded wires
●
Twist the strands together, then insert the
wire into one of the quick coupling terminals.
Release button
To ensure that the wire won't bend, press
the release button while inserting into
terminal.
fr : French
nl : Dutch
it : Italian
jp : Japanese
11mm
R e c o m m e n d e d w i r e
diameter: 1.0 mm (18AWG)