Water Supply
CAUTION
!
Observe and follow all local building codes when installing
this appliance.
This ice machine must be connected to a potable cold wa-
ter supply line. delivering water pressure between a mini-
mum of 20 psi and a maximum of 120 psi.
Use
" copper tubing for your water supply which is avail-
1
4
able at any local hardware or plumbing supply store. Route
the
" copper tubing to suit your installation being sure not
1
4
to kink the tubing. Purchase enough copper tubing length to
allow a coil to be formed behind the unit for a "service loop"
which will allow the appliance to be pulled out from the
installation for servicing or cleaning. (See Figure 11). Con-
nect the copper tubing to the "top side" of a cold water pipe
to prevent the ice-maker from plugging with sediment.
A shutoff valve is recommended on the water supply line to
ease servicing the appliance. NOTE: A SELF-PIERCING
TYPE VALVE IS NOT RECOMMENDED as they are prone
to clogging with sediment which will create pressure drop
reducing the water supply to the unit.
Connect the copper tubing water supply to the water valve
inlet with the compression nut fitting provided.
IMPORTANT: Secure the water supply line to the back of
the cabinet with the screw and strain relief clamp provided
in the corner of the back panel. (See Figure 11).
Make certain all connections are watertight after installa-
tion. Form the tubing so that it will not vibrate against the
cabinet body or kink when your appliance is moved in and
out of position.
This ice machine is designed to make clear ice from the
majority of water sources on a daily basis. If your results
are unsatisfactory, your water may need to be filtered or
treated. A water specialist can recommend proper water
treatment.
CAUTION
!
To prevent water leaks:
The water line fitting is to be used with copper tubing
only. Do not use with plastic tubing.
Do not use any thread sealers on this water line fitting.

INSTALLING THE WATER SUPPLY

8
Water supply
service loop
to shut off
valve
Figure 11
Back view of
ice machine
Compression
fitting
Water valve
inlet
NOTE
Reverse osmosis, (RO), water, softened water, and de-
ionized water are not recommended as they can adversely
affect the quality and quantity of the ice.
Water
Supply
Line
Clamp and
Screw
Water
supply
line

Publicidad