CHANGING THE DECELERATION ZONE ON CLOSING
The control unit has a pre-programmed deceleration zone (default).
Procedure:
1) After point 10 of "
3) Continue programming according to points 11 and 12.
The memorised values remain stored until a new programming cycle is performed.

MANUAL PROGRAMMING

This programming mode envisages that the operator stops door closure in advance with an S/S command.
The aim of this operation is to reduce the time required for the learning process and avoid excessive mechanical stress.
Procedure:
1-2-3-4) See "
5) Press the S/S button to start the self-learning process. The door starts closing.
7) When closed completely, press S/S to stop the door.
8) The door starts opening after a brief interval.
9) Press S/S when the door reaches the required opening position.
10) The door stops and the unit memorises the pause time.
11) If automatic closure is not enabled, press the S/S button immediately; otherwise wait for the required pause time, press
the S/S button and the door starts closing.
stop the door at the end of closure.
15) Door completely closed; led LD1 turns off.
16) End of programming (the control unit sets automatically to normal operating mode). .
FUNCTION SETTINGS (table 3)
58
" press the S/S button again when the required deceleration zone is reached.
".