WRF143/186
Installation Instructions/Инструкция по
установке/Instrucciones de Instalación
הוראות התקנה
English, Русский, Español,
WRF
4
WRF143/186 Wireless Expander
The WRF is a FastLink technology wireless expander that allows the FORCE and FORCE Lite alarm systems, to transmit and receive
transmissions from PIMA's wireless detectors and peripherals, making the two alarm systems hybrid ones. The transmissions are routed
to and from the control panel over the bus.
The WRF can alert on jamming, and has a back tamper switch. For full information, see the FORCE Installation guide (P/N: 4410459).
Technical specifications
Frequency:
WRF143: 433.92 MHz
o
WRF186: 868.85MHz
o
Operating Input Voltage: 9-15VDC
Content of the product package
WRF143/186 Expander + Bus Connector
Mounting guidelines
Mount the WRF where the wireless signal is high, and it can be connected to the control panel.
Do not mount the expander inside a metal enclosure or on metalized wallpaper.
Mount the expander at least 2 meters away from any electrical device that generates noise.
The expander must not be exposed to direct heat sources and sunlight, or strong artificial light.
Contact with spraying or dripping water and aggressive liquids must be avoided.
How to mount and connect the WRF
Mount the expander on a flat surface. Follow the next steps.
1.
Insert a slotted screwdriver to the niches at the bottom of the expander and remove the cover.
2.
Pass the four bus wires (not supplied) through the back plate and mount the plate.
3.
Connect the bus wires using the supplied connector, making sure to follow the numbering on both the control panel and the
expander (terminal #1 on the control panel connects to the same terminal on the expander, etc.).
4.
Set the expander in the control panel and check the LEDs; see below.
5.
Click the expander into the back plate.
6.
Test the expander.
The LEDs
LED
State
Run Green
Flashing
Flashing infrequently (single)
Bus
Red
Flashing infrequently (double) Communicating - registered device
Flashing (single)
Rx
Red
Flashing (double)
Ordering Information
WRF143 P/N: 8500030
עברית
1 Mounting Holes
1
2 Tamper Switch
3 BUS Terminals
4 BUS Cable
5 FORCE's Control Panel
2
6 FORCE BUS Terminals
1
2
3
4
3
1 Agujeros de Montaje
2 Suiche Tamper
5
3 Terminales del FORCE BUS
4 Cable BUS
5 Panel de Control FORCE
6 Terminales del FORCE BUS
6
Dimensions: 15 X 12 X 3 cm
Weight: 200gr
CE Compliance
Operating Temperature: -10 to +50 °C
Description
Device OK
Communicating - unregistered device
Intercepting - unregistered device
Intercepting - registered device
WRF186 P/N: 8500031
This guide
1 Монтажные отверстия
2 Тампер
3 Клеммная колодка FORCE BUS
расширителя
4 Кабель шины FORCE BUS
5 Контрольная панель FORCE
6 Клеммная колодка FORCE BUS
контрольной панели
התקנה
2 מפסק טמפר
FORCE BUS
Bus
FORCE
לוח הבקרה של
FORCE BUS
Humidity (Max.): 93% R.H., Non-
condensing.
חורי
1
חיבורי
3
- ה
כבל
4
5
חיבורי
6