Configuring The Keypad - SOMFY VSYSTEMPRO Manual De Instalación Y De Uso

Ocultar thumbs Ver también para VSYSTEMPRO:
Tabla de contenido

Publicidad

Electrical door-opener controlled by a "normally closed" contact
The keypad is configured to work in normal open mode (NO) using its 3 relay outputs.
If one of the relays is used in normally closed mode (NC), it is necessary to position the
jumper that matches this relay in the "NC" position:
E.g.:
MOV
SW1 and SW2 terminals
It is possible to wire a push-button between the SW1 terminal and the "-" terminal in order
to be able to activate relay 1 with the same parameters as the keypad.
It is possible to wire a push-button between the SW2 terminal and the "-" terminal in order
to be able to activate relay 2 with the same parameters as the keypad.
To access parameter setting, the master code needs to be entered twice.
The default master code is: 11111111
Note: Each time a button on the keypad is touched it emits a short beeping sound.
3 CONFIGURING THE KEYPAD
Copyright © 2016 Somfy SAS. All rights
Relay 1
Relay 2
Relay 3
reserved.
EN
NO
NC
NO
6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

5132043a

Tabla de contenido