WATER CONNECTION

Fig. 1
Proper water connection.
3.0

INSTALLATION

3.1

HIGH PRESSURE HOSE

Remove and discard the water plug (12 parts list) before attaching the high pressure hose by
carefully inserting the fitting with the o-ring into the high pressure outlet and tighten the threaded
nut by hand.
3.2
WATER CONNECTION
Before connecting, run water through the garden hose (not supplied) to flush out any foreign
matter. Attach garden hose to the pressure washer water inlet connection.
3.3
POWER SUPPLY CONNECTION
The pressure washer is factory-equipped with an electrical cord and a Ground Fault Circuit
Interrupter (GFCI) power plug.
This cord should only be connected to an electrical outlet installed in accordance with local safety
regulations.
NOTE: The power supply must be 120v, 60hz and a minimum 15 amp circuit.
Test GFCI before each use. DO NOT use pressure washer if test below fails.
GFCI Test Procedures:
1. Plug GFCI into power receptacle
2. Press reset button
3. Press test button.
4. Press reset button again for use.
NOTE: The GFCI must be reset each time the pressure washer is connected to an electrical outlet.
Reset by simply pushing the reset button on the GFCI power plug.