5. TYPICAL INSTALLATIONS
5.3
S
A
TAND
LONE
(Primarily for homes with no central air mover or equipped with wall furnaces, radiant hot water or electric baseboard heating.)
5.3.1 B
ASEMENT
• Ideal for homes without a central furnace
in the basement. Allows filtration and a
better air circulation throughout the house.
• Easy access to perform the periodic filter
maintenance and servicing.
• Offers an ambient temperature above
freezing (32°F - 0°C).
• The HEPA Filtration model GSFH1K has
no connection to the outside, so all parts
encircled are not required.
INSTALLATION CONSIDERATIONS:
• Installing the unit near an exterior wall will
shorten the length of the insulated ducts
(not necessary for HEPA Filtration only
model GSFH1K).
• If a HEPA Filtration Fresh Air & Heat
Recovery Ventilation model GSHH3K is
installed, a water drain must be close to
collect the run-off.
5.3.2
G
C
ARAGE
LOSET
• Ideal for homes without a central furnace,
or limited space applications, allows filtration
and a better air circulation throughout the
house.
• Easy access to perform the periodic
maintenance (twice a year).
• The HEPA Filtration model GSFH1K has
no connection to outside, so all parts
encircled are not required.
When the ambient temperature for the unit location is below freezing (32°F - 0°C), the unit must run continuously to prevent
condensation.
INSTALLATION CONSIDERATIONS:
• Installing the unit near an exterior wall will shorten the length of the insulated ducts
(not necessary for HEPA Filtration model GSFH1K).
• If a HEPA Filtration Fresh Air & Heat Recovery Ventilation model GSHH3K is installed, a water drain must be close to collect
the run-off.
• All ducts must be insulated.
• For the HEPA Filtration, Fresh Air & Heat Recovery Ventilation (GSHH3K) and the HEPA Filtration, Fresh Air & Energy
Recovery Ventilation (GSEH3K) models only, if the ambient temperature around the unit drops below freezing (32°F - 0°C),
go to Section 6.11 (Low Temperature Applications) for instructions on drain line protection (GSHH3K only) and other cold
environment installation details.
(CONT'D)
I
NSTALLATION
Only for the models GSVH1K,
GSHH3K and GSEH3K that
use fresh outside air.
VH0039
VH0046
CAUTION
- 11 -
Drain required only for the
GSHH3K model.
Only for the models GSVH1K,
GSHH3K and GSEH3K that
use fresh outside air.