OBSERVE
A LL LOCAL CODES AND
ORDINANCES.
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD
GROUND PRONG.
ELECTRICAL
GROUND IS REQUIRED ON
THIS APPLIANCE.
For 230/208 volt 60 Hz, AC only, 15A fused
and properly grounded electrical supply is
required. A time delay fuse or time delay circuit
breaker is recommended.
Use a dedicated
circuit, serving only this appliance.
DO NOT USE AN EXTENSION CORD.
RECOMMENDED
GROUNDING
METHOD
For your personal safety, this appliance must
be grounded. This appliance has a power
supply cord with a 3-prong grounding plug. To
minimize possible shock hazard, the cord must
be plugged into a mating grounding type wall
receptacle and grounded in accordance with
the National Electrical Code (ANSt/NFPA 70)
latest edition and all local codes and
ordinances. If a mating wall receptacle is not
available, it is the personal responsibility and
obligation of the customer to have a properly
grounded 3-prong wall receptacle installed by a
qualified electrician.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result
in death, fire, or electrical shock.
_3-prong
I _
I
grounding
_-prong -......,<...--._ I /_ _ _
]
type wall
grouncung
_
plug
k._
receptacle
Power
till
Ground
supply
"
prong
cord
You can choose
between
two methods
below
according
to your window
sill shape
and preference.
USING
SLIT "A"
Fasten the stopper using 2 screw holes, and lead
out the power cord through slit "A".
USING SLIT "B"
Fasten
the stopper
using left screw
hole, and rotate
properly
to lead the power
cord out through
slit "B".
Power Cord