5 Keep the guide block (4) in the lower position (lift down).
6 Place the compressed-air motor (5) against the gas nozzle (2) with the distance sleeve placed
on top (7).
7 Fasten the adjusted motor position by means of the screws (3).
8 Move the torch out the clamping device (1) and remove the distance sleeve (7) from the
milling cutter (6).
NOTE
Make sure that only clean and dry compressed air is used.
The compressed air must correspond at least to the quality class 4 according to ISO 8573-1.
5.7 Establishing the electrical connection
Four robot outputs 24 V DC and one robot input 24 V DC are required for controlling the valve.
NOTE
The cleaning station must be and remain without compressed air and tension during setup!
• The gas nozzle diameter must match the one of the prism.
• The distance sleeve must match the nominal diameter of the gas nozzle.
• The milling cutter must be adapted exactly to the torch type.
Fig. 9
PE
X1
4
1
2
3
S1
Y2
XPE1
Electrical connection
Y2
5
6
7
8
X5.2
X3.2
Y3
X3.1
X5.1
X1.2
X1.3
5 Putting into operation
Y3
Y1
S1
10
11
9
12
X2.1
Y1
X2.2
X1.1
EN - 12