Cerwin-Vega! CVP-2153 & CVP-1152 Loudspeaker Systems

10. SUSPENSION OF THE CVP SERIES

Remove the fly bracket screws in the fly points where you want to install M10 eye bolts. Screw in the M10 eye
bolts being careful not to strip the fly bracket screw insert point. Do not remove fly bracket screws from areas
where you will not install eye bolts – insure that either an eye bolt or a fly bracket screw is installed in all fly
bracket screw insert locations.
De-rating
Using the mounting points at an angle will de-rate the WLL (Working Load Limit) for each mounting point. Each
point mounted at an angle should be de-rated according to the following formula.
-
WLL = cosine (angle) x 500
-
Where: angle = degrees form vertical pull
500 = WLL for each CVP mounting point @ vertical pull

11. SPECIFICATIONS

Cerwin-Vega! Loudspeaker Systems
Frequency Range -10 dB
Frequency Response -3 dB
Sensitivity @ 1w / 1 Meter
Power Capacity RMS / PK
Recommend Amplifier Power
Maximum SPL
Coverage Pattern
HF Diaphragm Size
Weight
Fly Points
Bi Amp use
Rotatable Horn
HF Protection
Woofer
Construction
Finish
CVP-1152
50 Hz - 20 kHz
59 Hz - 18.5 kHz
99 dB
500 / 1000 w
750 w - 1000 w
130 dB
60 x 40 rotatable
1.75"
66.5 lbs
Yes
Yes
Yes
Fast Reacting Suppression Limiter
Ceramic 3" VC
Multi-ply Hardwood
Polyurethane Paint
11
CVP-2153
37 Hz - 20 kHz
48 Hz - 18.5 kHz
101 dB
1000 / 2000 w
1500 w - 2000 w
134 dB
60 x 40 rotatable
1.75"
112.5 lbs
Yes
Yes
Yes