Descargar Imprimir esta página

Cooper Wiring Devices ASPIRE RFWC5 Guía Para El Usuario página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

The Wallmount 5-Scene Controller (RFWC5) is an ASPIRE RF™ controller that provides the User the ability to
launch preset scenes with the touch of a single button. It includes five buttons that can activate five indi-
vidual scenes, as well as a 6th button that serves as an "ALL OFF" feature.
A Cooper Wiring Devices' ASPIRE RF Tabletop Controller (RFTDCSG) or Handheld Controller (RFHDCSG) is
required to create and transfer scenes into the RFWC5.
The RFWC5 can be placed at entranceways, or in a convenient location where control of multiple
scenes is desired. Scenes are groups of preconfigured settings for individual devices (switches,
receptacles, dimmers, etc. ).
NOTE: Refer to the ASPIRE RF User Manual (included with the RFTDCSG or RFHDCSG) for detailed network
instructions.
INSTALLATION:
Refer to instructions provided on the inside of the package.
CAUTION: Power should be turned off, and verified to be off, before wiring any
electrical device.
The RFWC5 requires 120V/AC connected to the Black and White wires, and
grounding the green ground wire.
Connect the RFWC5 per the diagram including connection of the green ground
wire.
RFWC5 SCENE CONTROLLER NETWORK INSTALLATION INSTRUCTIONS:
This product may be added to a new or existing Z-Wave network. The RFWC5 has
blue LEDs which will all blink when the device is not included in a Z-Wave network.
The LEDs will not blink when the device is in a network. The blinking LEDs will
indicate that the device has power, but is not yet installed in the network.
• To include this device in a Z-Wave network, select the command on your
Z-Wave controller for inclusion (Install, Add Device, Add Node, Include Device,
etc.). Then press the All Off (Inclusion) button one time to include it in the network. The LEDs will blink
sequentially while the device is installing itself. DO NOT press any buttons while the device LEDs are
blinking sequentially. After installation is complete the LEDs will stop blinking.
• To exclude this device from a Z-Wave network, select the command on your Z-Wave controller for
exclusion (Uninstall, Remove Device, Remove Node, Exclude Device, etc.). Then press the ALL OFF
(Inclusion) button one time to exclude it from the network. The LEDs will start blinking, indicating
that the device is no longer in the network.
• This product works with other Z-Wave products from different vendors and product categories as part
of the same network.
• To replicate to this product from non-Cooper controllers, select the Replicate Send function on the
non-Cooper controller (refer to their manual) and press the ALL OFF (Inclusion) button on the RFWC5.
When the replication process is complete, the blinking LEDs on the RFWC5 will turn off.
INSTALLATION USING COOPER CONTROLLERS (RFHDCSG OR RFTDCSG):
After installation of the RFWC5, and power is applied, all 5 button LED's will blink. This will indicate that
the device has power, but is not yet installed in the RF network.
To install the RFWC5 in the network, the RFTDCSG or RFHDCSG Controller may be used. Follow the
detailed instructions in the ASPIRE RF User Guide - Section II.
This involves selecting the "Devices" menu, and then the "Install" feature on the Controller. After
selecting "Install" press the "ALL OFF" button on the RFWC5. The LEDs will stop blinking when the device
has been successfully added to the network.
PROGRAMMING SCENES:
Scenes are created with the use of a separate controller. This may be done with either the RFTDCSG or
RFHDCSG. The details on how to create scenes are included in Section II of the ASPIRE RF User Guide
(included with the Controllers).
After the scenes are created with either RFTDCSG or RFHDCSG they are transferred to the selected
button on the RFWC5 one-by-one, using the following steps:
Scene Button 1
Scene Button 2
Scene Button 3
Scene Button 4
Scene Button 5
Scene Status LED
1. Using either controller select "SCENES" from the main menu.
2. Select from this menu item "TRANSFER TO RFWC5".
3. Select the scene to be transferred using the control button.
Press the center ("OK") button to select the specific scene.
The screen will display a prompt that tells the user to press
the desired scene button on the RFWC5. ("Press and hold
the desired scene button on the device.") Release the
ALL/OFF
button when the LED begins to blink.
Button
4. After pressing the selected RFWC5 button the controller will
display that the transfer is in process, and will indicate when
it has been completed successfully ("Transfer to RFWC5 is
complete").
5 The scene button selected will flash while waiting for the
transfer scene information process to be completed.
6. When the scene has been properly transferred the LED
indicator for the chosen button will turn off.
7. The programmed scene button can now be tested by
pressing it to activate the scene.

Publicidad

loading