Affects
: dev:////pci@400/pci@1/pci@0/pci@c
dev:////pci@400/pci@1/pci@0/pci@c/pci@0
FRU
: "/SYS/MB" (hc://:product-id=ORCL,SPARC-T3-1B:product-sn=
1052NND107:server-id=dt214-154:chassis-id=0000000-0000000000:serial=1005LCB-
1052D9008K:part=541-424304:revision=50/chassis=0/motherboard=0) 67%
"FEM0" (hc://:product-id=ORCL,SPARC-T3-1B:product-sn=
1052NND107:server-id=dt214-154:chassis-id=0000000-0000000000/chassis=
0/motherboard=0/hostbridge=0/pciexrc=0/pciexbus=1/pciexdev=0/pciexfn=
0/pciexbus=2/pciexdev=12/pciexfn=0/pciexbus=62/pciexdev=0) 33%
Description : Too many recovered bus errors have been detected, which indicates
a problem with the specified bus or with the specified
transmitting device. This may degrade into an unrecoverable
fault.
Refer to http://sun.com/msg/PCIEX-8000-KP for more information.
Response
: One or more device instances may be disabled
Impact
: Loss of services provided by the device instances associated with
this fault
Action
: If a plug-in card is involved check for badly-seated cards or
bent pins. Otherwise schedule a repair procedure to replace the
affected device.
contact Sun for support.
Estos errores pueden indicar que el EM PCI está defectuoso o mal colocado. También
es posible que estos errores sean incorrectos.
Solución alternativa: asegúrese de que el EM PCI esté colocado correctamente y
funcione bien. Si los errores continúan, aplique el parche del sistema operativo
Oracle Solaris 10 8/11 147705-01 (o superior).
26
Notas del producto del módulo de servidor SPARC T4-1B • Diciembre de 2011
faulted but still in service
faulty
Use fmadm faulty to identify the device or