air. If you cover it you run the risk of it over-heating.
- Do not use the radiator to dry clothes as it is a fire-hazard.
- Do not handle the appliance with wet hands.
- When you clean it always take the precaution of disconnecting the appliance.
- It must be installed by a technical electrician.
Important: These appliances must be properly earthed.
- In case of fixed connection, a device between the appliance and the main supply
should be placed to guarantee the disconnection with an opening distance of the
contacts that permits the complete disconnection in the category III of overtension
conditions, according to the installation regulation.
-
The radiator can only be repaired at one of our Technical Service Offices.
-
If you detect a slight fluid leak, this may be due to a residual drop that forms in the
automatic jets on the assembly line at the end of a certain number of fills. Please clean
the affected area to see if the situation repeats itself. In the event of the leak appearing
again, please contact your nearest ACESOL retail outlet, or PDA where you purchased
the radiator so that it can be replaced as soon as possible.
- When scrapping the heater, follow the regulations concerning the disposal of oil.

3. Installation.

These radiators are for fixed installation and in order to install them follow the
instructions below:
Location.
The radiator must be located as close as possible to exterior walls; the thermal
emission efficiency is shown in the graphic design radiator placement. (Fig. 1 - 5)
In bathrooms, the radiators must be installed beyond the prohibited and protection
limits (Fig. 6)
Wall instalation.
The radiator is fixed to the wall by 2 specially designed supports, using the PVC rawl-
plugs and the screws which are enclosed in the packaging. Y ou should make sure that
the rawl-plugs and the screws provided are suitable for the type of wall on which the
radiator is going to be located. The supports are located in the lower back part of the
emitter, packaged next to the accessories necessary for its installation.
The minimum distance between the floor and the base of the radiator
must be 100 mm.
To install follow the procedure below:
1. Mark the location of the upper supports according to Fig. 7/8, following the distances
in the attached table. Use a support as a template to mark where the holes should be.
Drill the holes and put in the rawl-plugs.
2. Fix the two supports for the radiator with the four screws provided.
3.
Fit the radiator to the brackets provided for this purpose.
Electrical connection.
- They are fixed installation radiators. In order to connect them to the mains circuit, you
should take into account the guidelines which are shown in the Low Voltage Regula-
Classic