Activating the remote control
A. insert the existing AF card.
B. store code in the motherboard.
d
- The AF board should
ALWAYS be inserted
when the power is off because the motherboard
only recognises it when it is powered.
Trimmers regolation
- AMP SENS (SENS VEL) = Ad-
justment of amperometric
sensitivity during operating:
MIN/MAX;
N.B.: once the installation is completed, you need to memorize the
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s.p.a.
Memorisation
- Keep the CH1 key pressed on the base card (the signal LED will fl ash), and with a key on the
transmitter the code is sent, the LED
code.
- Perform the same procedure with the "CH2" key, associating it with another transmitter key.
CH1 = Channel for direct control of one function performed by the control unit on the gear motor
(for the type of command, see the function selector)
CH2 = Channel for direct control of an accessory connected across B1-B2 (it may be used only
if enabled).
N.B. If you wish to change the code on your transmitters in the future, simply repeat the procedure
described above.
- SLOW DOWN (SENS RALL) = Adju-
stment of amperometric sensitivity
during slowdown: MIN/MAX;
operating time in the following way:
c
will remain lit to signal the successful saving of the
- OP TIME (TL) = Adjusting of the
stop zone (open/closed position).
1 - select the dip 6 in ON;
2 - keep CH1 pressed until the gate is completely open;
3 - keep CH2 pressed until the gate is completely closed;
4 - select the dip 6 in OFF.
- ACT (TCA) = Adjustment
of automatic closing time: 1"
to 120";