heavier, more absorbant materials. The Solution Flow
Guide diagrams (Fig. E) provide a rough guide for light,
medium and maximum flow adjustments.
Vacuum control. Use the vacuum release slide (Fig. B,
1) to control the strength of the vacuum when extracting
thin, delicate or lightweight fabrics.
FIG. B: HEAD ASSEMBLY
1. Vacuum
release slide
2. Upper
cover
FIG. C: HEAD (BOTTOM VIEW)
1. Trigger lever
2. Trigger lever lock
FIG. D: FLOW ADJUST ASSEMBLY
1. Control knob
4. Orifice plate
(20-035)
07-01713B 2010-05
3. Cover
screws (×4)
4. Trigger valve
body (23-070)
5. Glide screws (×4)
Remove upper cover first.
6. Glide and O-ring seal
(S13-01705)
3. Front quick-
connect coupling
4. Vacuum cuff
attachment
5. Trigger lever nut
and bolt
6. Glide
3. Hex nut. Loosen
2. Inline strainer
here to access strainer.
(20-006)
5. Washer
6. Rear quick-
(24-002)
connect coupling
For best results, use the Upholstery Pro with Sapphire
Scientific cleaning chemicals.
For more information about cleaning with the Upholstery
Tool, visit www.sapphirescientific.com.
MAINTENANCE
Daily: Rinse the hand tool by running clean water
through the solution line.
Daily: Check the glide assembly (Fig. C, 6) for steady,
even flow of solution through the injector nozzles. If any
of the injector ports appear clogged, use a small needle
to remove the obstruction, taking care not to damage the
glide. If the glide is scratched, gouged, snags on
carpets, or flows excessively, it may need to be replaced
(see "Servicing the glide," below). Replacement glide
assemblies are available from your distributor.
As needed: Lubricate the quick-connect couplings
(Fig. C, 3; Fig. A, 6) with a small amount of rust-inhibiting
oil such as LPS-3.
As needed: Lubricate trigger valve stem (Fig. F) with
a small amount of synthetic heavy duty grease. To
grease the stem, follow these steps.
1. Remove the trigger lever nut and bolt from the
trigger lever and remove lever.
2. Unscrew stem retention nut and lift out stem
assembly. Apply a small amount of grease to the
stem.
3. Replace stem assembly and retighten retention nut.
Reattach trigger lever.
As needed: Clean the inline strainer (Fig. D, 2) when
solution flow is visibly reduced. To clean the filter, loosen
the strainer assembly nut, and remove the strainer and
strainer washer. Rinse these items in clean water and
reassemble the strainer. It is not normally necessary to
replace the inline filter element. Be sure to include the
nylon washer when reassembling, and take care not to
over-tighten the strainer assembly nut.
To maintain appearance, wipe exterior surfaces with a
damp cloth.