SITE PREPARATION
Electrical
Installation must comply with all applicable electrical codes.
The electrical supply must be located within the shaded
area shown in the illustration and chart below. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and may
cause interruption of operation.
The electrical outlet must be positioned with the grounding
prong to the right of the thinner blades.
CAUTION
The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.
WARNING
Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
ELECTRICAL SUPPLY LOCATION
WIDTH
18" Models
24" Models
27" Models
30" Models
36" Models
LEFT SIDE
OF OPENING
1
4
/
"
A
2
(114)
1
4
/
"
4
(108)
FLOOR
1
1
/
/
"
"
4
4
(6)
(6)
Electrical supply location.
115 VAC, 60 Hz
15 amp
3-prong grounding-type
A
6"
(152)
9
1
/
"
(241)
2
11"
(279)
1
12
/
"
(318)
2
15
1
/
"
(394)
2
Plumbing
Installation must comply with all applicable plumbing codes.
The water supply line should be located within the shaded
area shown in the illustration below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve. Do not use self-piercing valves.
The water supply line must be flush to the floor and not
interfere with installation of the anti-tip bracket.
Column and tall models with an ice maker or water dis-
penser feature a water filtration system. An in-line filter is
required for drawer models with an ice maker when water
conditions have a high sediment content.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
to the unit at all times. In this application, the water filtra-
tion system must be bypassed. Refer to water filter bypass
on page 15. A copper line is not recommended for this
application.
PLUMBING REQUIREMENTS
Water Supply Line
Water Pressure
Excess Water Line for Connection
WATER SUPPLY LOCATION
WIDTH
18" Models
24" Models
30" Models
36" Models
RIGHT SIDE
OF OPENING
A
6"
(152)
3"
(76)
AREA EXTENDS 1
/
"
2
(13)
FORWARD ON FLOOR
Water supply location.
supplied
(2.4–8.3 bar)
1
/
" OD copper, braided
4
stainless steel or PEX tubing
35–120 psi
(2.4–8.3 bar)
36"
(914)
A
3"
(76)
5
1
/
"
(140)
2
6"
(152)
9"
(229)
|
subzero.com
5