TECHNICAL FEATURES
- Nominal voltage:
- Frequency:
- Breaking power:
- Own consumption:
- Fuse:
Protected against power supply cuts of up to 10 min (after 1 hour of connection at
least)
- Precision:
- Temperature range:
Operating conditions ......................-10°C to +45°C
Operating limit conditions.................-20°C to +55°C
Storage conditions............................-25°C to +70°C
- Casing protection: IP 20 to UNE 20-324
- Immunity to rapid electrical transitories:
- Resistance to ray type pulses:
- Maximum number of coins or tokens:
- Timing by coin or token
- Maximum:
- Minimum:
- Coin types. Only one of the following types:
DIMENSIONS:
172
"CTM ELECTRÓNICO" PROGRAMMING EXAMPLES
Example 1: We wish an installation to operate with a minimum of 2 coins for which we
wish there to be a total timing of 1 hour, i.e.
1 coin = 0
2 coins = 1 hour
3 coins = 1 hour 30 minutes
4 coins = 2 hours
5 coins = 2 hours 30 minutes
For this we will have to configure the CTM ELECTRÓNICO in the following way:
- Turn SW1 until it indicates the number 2. In this way we define that timing
does not start until the second coin is inserted.
- Set SW2 switches 1, 2 and 5 to OFF and switches 3 and 4 to ON (normal
timing = 30 minutes/coin).
- Turn SW4 until it indicates the number 0. In this way we deactivate
special timing.
- Press the RESET button (SW7) to validate the programme.
Example 2: We wish to regulate the use of an installation in such a way that each coin
has a timing time of 1 hour but each coin after the fourth coin has a timing time of 3
hours, i.e.
1 coin = 1 hour
2 coins = 2 hours
3 coins = 3 hours
4 coins = 12 hours
5 coins = 15 hours
6 coins = 18 hours
Furthermore, we wish the early warning to be activated 30 seconds before the end of
the metered time. For this we will have to configure the CTM ELECTRÓNICO in the
following way:
- Turn SW1 until it indicates the number 1. In this way we define that timing
will start when the user inserts the first coin.
- Set SW2 switches 1, 2, 3 and 4 to OFF and switch 5 to ON (normal
timing = 1 hour/coin).
- Turn SW4 until it indicates the number 4 (special timing after the fourth
coin).
- Set SW3 switches 1, 3 and 4 to OFF and switches 2 and 5 to ON (special
timing = 3 hours/coin). - Set SW3 switch 6 to OFF (short early warning).
- Press the RESET button (SW7) to validate the programme.
See rating plate
45-60 Hz
16A – 4A X 250 V ~
5 VA
100 mA
±0.2%
Level 3 to IEC 801-4
6 kv 12/50 μs to UNE 20.324
99
150 hours/coin
1 minute/coin
0,50€, 1€ and 2€.
119
ORBIS TECNOLOGÍA ELÉCTRICA, S.A.
Lérida, 61
Teléfono:+ 34 91 5672277;
Example 3: We wish an installation to operate with a minimum of three coins for which
we wish there to be a total timing of 1 hour, i.e.
1 coin = 0
2 coins = 0
3 coins = 1 hour
4 coins = 1 hour 20 minutes
5 coins = 1 hour 40 minutes
6 coins = 2 hours
Furthermore, we wish the early warning to be activated 4 minutes before the end of the
metered time. For this configuration we will have to:
- Turn SW1 until it indicates the number 3. In this way we define that timing
does not start until the third coin is inserted.
- Set SW2 switches 3 and 5 to OFF and switches 1, 2 and 4 to ON (normal
timing = 20 minutes/coin).
- Turn SW4 until it indicates the number 0. In this way we deactivate
special timing.
- Set SW3 switch 6 to ON (long early warning)
- Press the RESET button (SW7) to validate the programme.
E–28020 MADRID
Fax:+34 91 5714006
E-mail: info@ orbis.es
http://www.orbis.es
A016.12.49199