6. Open the two shut-off valves (2, 3) and close the shut-off (1) for filling.
7. Fill the system with solar liquid via the shut-off valve (2).
8. As soon as solar liquid escapes via the lower shut-off valve (3), close this
shut-off valve.
9. Apply pressure to the system.
10.Close the upper shut-off valve (2).
11.Turn the shut-off (1) back.
12.Vent the system (see chapter "Venting the system").
13.Set the two ball valves to 0° position.
14.Fit the upper part of the insulation onto the fitting group.
15.Make sure the pipe insulation reaches into the corresponding recess of
the insulation of the product.
Commissioning
PrimoSol® 130
EN
19