Dea SSE12 Instrucciones De Uso Y Advertencias página 12

Alimentador para usos genéricos
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Operating instructions and warnings
only for qualified personnel
DIP1
DIP2
OFF
OFF
DIP1
DIP2
OFF
ON
10
Table 2 operating programs
Monostable:
relay=ON when IN1 or IN2 = maintained activ.
relay=OFF when IN1 and IN2 = not activ.
RELAY MODE ACCORDING TO INPUTS MODE
Monostable without any delay:
ON
OFF
ON
OFF
Monostable with delay at turning off
(delay_off):
DELAY_OFF
DELAY_OFF
ON
OFF
ON
OFF
Bistable:
the impulsive activation of IN1 or IN2 causes the relay mode changing.
RELAY MODE ACCORDING TO INPUTS MODE
Bistable without delays:
ON
OFF
ON
OFF
Bistable with delay at turning off (de-
lay_off):
DELAY_OFF
ON
OFF
ON
OFF
N.B. : Other incidental inputs on IN1 or
IN2 during "delay_off", are not consi-
dered.
PROGRAM DESCRIPTION
Monostable with delay at turning on
(delay_on):
ON
IN1 or IN2
OFF
ON
RELE'
OFF
DELAY_OFF
IN1 or IN2
RELE'
PROGRAM DESCRIPTION
Bistable with delay at turning on (de-
lay_on):
DELAY_ON
ON
OFF
IN1 or IN2
ON
OFF
RELE'
N.B. : Other incidental inputs on IN1
or IN2 during "delay_on", are not con-
sidered.
DELAY_OFF
IN1 or IN2
RELE'
DELAY_ON
DELAY_ON
DELAY_ON
IN1 or IN2
RELE'
IN1 or IN2
RELE'

Publicidad

Tabla de contenido
loading

Tabla de contenido