INSTALLATION
MOUNT PUMP
Pump must be mounted vertically with pump head pointed downward.
Select a dry location (to avoid water intrusion and pump damage) above the
solution tank. Best recommended location is above the solution tank in a
vertical position with the pump head pointed downward and the spill recovery
(see page 13) in place to reduce the risk and severity of damage.
To prevent pump damage in the event of a pump tube leak, never mount the
pump vertically with the pump head up.
To avoid chemical damage from fumes, DO NOT mount pump directly over an
open solution tank. Keep tank covered.
Avoid flooded suction or pump mounted lower than the solution container. Draw
solution from the top of the tank. Pump can run dry without damage. If pump is
installed with a flooded suction, a shut-off valve or other device must be
provided to stop flow to pump during service.
1. Use the mounting bracket as a template
to drill pilot holes in mounting location.
2. Secure bracket with fasteners or wall
anchors. Slide pump into bracket.
Provide 8" clearance to allow
pump removal.
To prevent damage, verify with a volt
meter that the receptacle voltage
corresponds with the pump voltage.
12
continued
www.stenner.com