Pre-Installation (continued)
4 IN. PUMP DESIGN AND OPTIMUM PERFORMANCE
The 4 in. submersible well pumps sold in retail outlets are designed to pump 10 gallons per minute (10 GPM), which is the average size
home's use of water per minute. Larger homes will require larger pumps. 4 in. pumps are built with multiple pumping stages, i.e., 6-10
stages, each lifting water to the next stage and to your application. Typically, the deeper the well, the more stages and more motor
horsepower are required to lift the water. The impellers rotating in each stage need to operate in the middle of the stage. Operating above
or below middle may cause the impeller to rub on other stage components, either shortening pump life and/or using excess energy (amp
draw).
PROPER 4 IN. PUMP SELECTION
The proper well depth and horsepower for 10 GPM 4 in. submersibles are as follows:
HP
GPM PUMP DEPTH IN WELL
1/2
10
60-100 ft.
3/4
10
100-175 ft.
1
10
175-250 ft.
NOTE: In irrigation applications, i.e. small farms, the stages are designed to pump 20 GPM and the depth of water as follows:
HP
1
VOLTAGE
4 in. submersible pumps are offered in 230V. Be sure the voltage of the pump you select matches the voltage of the well.
NUMBER OF PUMP WIRES AND CONTROL BOXES
4 in. pumps are offered in either 2 wire or 3 wire (the number of wires running from the pump motor).
2-wire motors have 3 wires running from the motor - 2 to provide electric service and 1 ground wire. The motor controls are in the
motor in the well.
2-wire motors are typically used in wells less than 300 ft. in depth and 3-wire motors are used in deeper depths.
Some users prefer their motor controls be readily available for service (3-wire and control box mounted near tank), while others
find it unnecessary.
3-wire motors have 4 wires running from the motor - 3 to provide electric service and 1 ground wire. These motors require a motor
control box mounted on the wall near your water tank.
3-wire installations will be more expensive. For example, your wire has more strands in it (4 vs. 3) and they are sold separately.
NOTE: Control box voltage and horsepower must match pump voltage and horsepower.
PUMP
HP
1/2
3/4
1
CONFIRMATION OF SELECTION
Knowing the above and prior to removing and reinstalling your 4in. pump, please confirm the following:
The correct HP for the depth the pump will sit in the well.
The correct GPM (gallons per minute) for your well.
The correct voltage.
The correct number of wires.
The correct control box (if applicable).
GPM PUMP DEPTH IN WELL
60-100 ft.
20
CONTROL BOX
VOLTAGE
HP
230
1/2
230
3/4
230
1
VOLTAGE
230
230
230
4