Cedes cegard/Mini-CC Guia De Instalacion página 4

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 14
cegard/Mini-CC
Selectable output logic
NO/NC selector connected to GND (0 V)
U
Output
0 V
NO/NC selector connected to U
U
Output
0 V
PNP/NPN output
cegard/Mini-CC
U
SP
Output
µC
GND (0 V)
Selectable output logic
Electrical connections are compatible with the CEDES MiniMax series.
4. Switch on the cegard/Mini-CC and test for correct function using the status LEDs on both edges.
Edge
LED Color
Receiver (Rx)
Orange
Emitter (Tx)
Green
Troubleshooting
Sensor status
General / unknown problem
Receiver edge output (black wire) is HIGH when the
detection area is free.
Receiver edge output (black wire) is LOW when the
detection area is free.
Output signal is unstable when the elevator door closes.
Elevator doors are closing even when objects enter the
detection area.
4
SP
or not connected
SP
SP
M8, 4-pin
LED ON
Power OK
object detected
Power OK
brown
Load
black
blue
white
LED OFF
No power or no object
detected
No power
Action
` Power off both cegard/Mini-CC edges and restart.
` Check if the supply voltage on both edges is between
10 VDC and 30 VDC.
` Check LED function (see "Mounting instructions").
` Connect output selector (white wire) on the receiver with
GND (blue wire), see "Selectable output logic".
` Connect output selector (white wire) on the receiver with
U
(brown wire), see "Selectable output logic".
SP
` Make sure no objects such as the door interlock assembly
enter the detection area during closure.
` Make sure the edges do not swing or vibrate during
closure.
` Make sure the edges are not covered by dust or dirt.
` Make sure the receiver edge is not directly exposed to
strong infrared light sources such as sunlight.
` Make sure the NO/NC selector is set correctly.
NPN
i
NPN
English
PNP
Load
i
PNP
© CEDES | V 2.0

Publicidad

Tabla de contenido
loading

Tabla de contenido