This appliance is intended for
connection to fixed wiring. Check
that the electrical rating shown on
each fan matches the mains supply.
THE APPLIANCE IS DOUBLE INSULATED
AND DOES NOT REQUIRE AN EARTH
CONNECTION. All installations must be supervised
by a qualified electrician. Installations and wiring
must conform to current IEE Regulations (UK), local
or appropriate regulations (other countries).
This appliance can be used
by children aged from 8 years
and above and persons with
reduced physical, sensory
capabilities or lack of
experience and knowledge
if they have been given
supervision or instruction
concerning the use of the
appliance in a safe way and
understand the hazards
involved. Children shall not
play with the appliance.
Cleaning and maintenance
of the appliance shall not be
made by children.
All Xpelair Simply Silent™ DX100 AC
fans have the following features:
• Two speed extraction
(Selectable at installation)
DX100R/DX100S - Operate the fan using an
on/off switch (not supplied).
DX100TR/DX100TS* - Built-in timer operates fan
for a preset delay from 30 seconds to 30 minutes.
DX100PR/DX100PS - Operate the fan using an
integral pull-cord.
DX150HTS/DX150HTR* - Operates when triggered
automatically by the integral humidity sensor, or by
using an external on/off switch (not supplied).
In automatic mode: the built-in timer automatically
operates the fan for a pre-set delay time from 30
seconds to 30 minutes once humidity drops below
the pre-set Relative Humidity (RH) value.
External operation: When switched off using the
external on/off switch the fan continues to run for
the preset delay from 30 seconds to 30 minutes.
DX100HPTR/DX100HPTS* - Operates when
triggered automatically by the integral humidity
sensor, by using an external on/off switch (not
supplied), or by using the integral pull cord switch.
In automatic mode: The built in timer automatically
operates the fan for the pre-set delay time from 30
seconds to 30 minutes once humidity drops below
the pre-set Relative Humidity (RH) value.
External operation: When switched off using
either the external on/off switch or the integral
pull cord switch the fan continues to run for the
pre-set delay from 30 seconds to 30 minutes.
DX100PIRR/DX100PIRS* - An integral body
movement sensor operates the fan as long
as movement is detected. The built-in timer
automatically operates the fan for a pre-set delay of
up to 20 minutes.
* Factory settings: Timer 15 minutes, RH 75%
Where to locate the fan.
• Locate it as high as possible.
• At least 110mm from the edges of
• As far away as possible from and opposite to
the main source of air replacement to ensure
airflow across the room (e.g. opposite the
internal doorway).
• Near the source of steam or odours.
• If installing in a room containing a fuel burning
device which has a non-balanced flue, it is the
installer's responsibility to ensure that there
is enough replacement air to prevent fumes
being drawn down the flue when the fan is
operating up to maximum extract. Refer to
Building Regulations for specific requirements.
• Exhaust air must not be discharged into
a flue used for exhausting of fumes from
appliances supplied with energy other than
electric. Requirements of all authorities
concerned must be observed for exhaust air
discharge and intake flow rates.
• Not suitable for use in possible chemical
corrosive atmospheres.
Installation
the mounting surface to the centre
of the hole.
• Not where ambient temperatures
are likely to exceed 50°C.
• If installed in a kitchen
fans must not be mounted
immediately above a cooker
hob, or eye level grill.
What the installer will need.
• 3mm electrician's screwdriver
and No.1 or 2 Pozidrive
screwdrivers.