Jandy
Pro Series Sand Filter SFTM22-1.5, SFTM24-2.0
®
The proper type, amount and cleanliness of your filter
sand is critical to the proper function and longevity of
your equipment.
#20 Silica Sand (for pool fi lter use only)
Size Range .40-.55 mm
Model
Lbs. (kg)
SFTM22-1.5
250 (113)
SFTM24-2.0
300 (136)
1. Make sure the filter is level on the equipment pad.
2. Prepare filter for sand.
a
Fill the filter 1/3 - 1/2 full of water before adding sand.
• This will minimize any undue strain on the laterals when
adding sand.
4.5 ASSEMBLE MULTIPORT VALVE
1. Install pressure gauge.
a
Remove the plug from the pressure gauge port.
Install pressure gauge.
b
• Screw into place until snug. DO NOT OVERTIGHTEN.
• If possible, orient the gauge so that it is horizontally
aligned. The included Teflon
getting the appropriate orientation and fit.
If possible, orient the gauge so that it is right reading and
c
perpendicular to ground level.
WARNING
PVC cement and primer can produce
vapors that can be hazardous to your
health. Use PVC cement to join pipes
only in a well ventilated area where
vapors cannot accumulate.
Pipe dope should NEVER be used
on plastic threads. Pipe dope will
severely weaken the plastic, causing
leakage and may cause the plastic to
fracture. DO NOT OVERTIGHTEN
SFTM24-2.0
d
b
a
Tailpiece
Union Nut
|
Installation & Operation Manual
NOTE: Alternate Filter Media
Manufacturers directions must be
followed for any alternate media. Use
of other media may deliver unexpected
results and may void the warranty.
tape can be used to aid in
®
SFTM22-1.5
d
d
Union Adapter
ENGLISH
Ensure stand pipe is seated at the bottom of the filter
b
tank.
c
Install the clear plastic stand pipe shield.
• The shield should completely cover the pipe opening.
• Special care should be taken to avoid getting filter sand into
the stand pipe.
Using a small scoop, slowly and evenly add sand to the
d
filter.
• Be sure to allow the stand pipe shield to fully drain between
each scoop to avoid spilling.
When all filter sand has been added:
3. Remove stand pipe shield and store for future use.
Install unions at the filter's Pump, Return and Waste ports.
d
• SFTM22-1.5 will use a union adapter at the waste port only.
• SFTM24-2.0 will use union adapters at the waste and return
ports. The extension adapter will be used at the pump port.
• Apply 4-6 wraps of PTFE (plumbers) tape for each union
adapter installed at the multiport valve. Only install PTFE
(plumbers) tape on the adapter threads at the valve ports.
• Do not use PTFE (plumbers) tape on union nut threads.
d
b
a
O-ring
Page 7
Union Nut
d
Tailpiece
O-ring
Union Adapter
d
Pressure Gauge
Ground Level
c