No gas flow
Regulator is not fully
connected to the tank
Gas flow is obstructed
Burner will not
Spider webs or insect nest in
light using a
the venturi (end of burner
match
tube)
Burner ports are clogged
Flame is obstructed at burner
Fire table emits
ports
a lot of black
smoke when lit
Regulator hose is pinched
No gas flow
Sudden drop in
gas flow
Excess flow safety valve has
been activated
High or gusting winds
No gas flow
Flame blow out
Excess flow safety valve has
been activated
Irregular flame
pattern or flame
does not come
Burner ports are clogged
out of the entire
length of the
burner
EXPEDITE YOUR REQUEST FEEL FREE TO EMAIL US
OR VISIT OUR WEBSITE UNDER CUSTOMER SERVICE SUPPORT
IF YOU HAVE QUESTIONS OR CONCERNS
PLEASE CALL BOND TOLL FREE #
1-866-771-BOND(2663) OR TO BETTER
customer.service@bondmfg.com
www.bondmfg.com
BOND MANUFACTURING CO.
1700 West 4th Street, Antioch, CA 94509
Check if gas cylinder is empty. If yes,
replace.
Check LP tank connection.
Check hose for bends or kinks
Clean the venturi
Insert an opened paperclip into each of
the burner ports to clean them. Ensure
the fire table is off and all parts are
cooled before attempting to clean the
burner ports
Make sure all the gas burner ports are
free of any lava rocks or debris to allow
the gas to flow freely.
Check the regulator hose for bends or
kinks
Check if gas cylinder is empty. If yes,
replace.
Turn the control knob to "OFF". Close the
LP tank valve and disconnect the
regulator from the tank. Turn the control
knob to "HIGH". Wait 1 minute. Turn the
control knob to "OFF". Reconnect
regulator to LP tank. Open tank valve
slowly. Light fire table as indicated in "To
Light" section.
Increase flame to "HIGH"
Check if gas cylinder is empty. If yes,
replace.
See "Sudden drop in gas flow" above
See "Burner will not light using a match"
above.
10