Clean the unit with a mild detergent and water solution. Dry with suitable cloth.
Store with the leg pins in the storage/transit holes, in a cool place out of direct sunlight. Avoid chemical vapors and physical damage to the unit.
Inspect after periods of prolonged storage.
Any repairs must be completed by the manufacture or a repair entity with written authorization to make repairs to this unit.
7. INSPECTION OF TRIPOD
Prior to each use, the user must inspect the tripod for any physical damage.
Inspect for:
1. Inspect the entire unit for signs of corrosion, cracks, and deformities
2. Inspect all fasteners to ensure each is securely tightened.
3. Inspect all locking and detent pins are in place
4. Ensure the foot of each leg is secure, with the rubber foot pad attached.
5. Ensure the chain is complete and in good working order.
6. Ensure the pulleys and eye bolts are secure
7. Inspect the labels to be sure they're present and legible
An inspection by a competent person other than the user is required every six months. Use the steps in this manual.
If routine inspection reveals an unsafe condition, tag the tripod as "UNUSABLE".
After a fall event, inspect the entire unit for damage.
Record the results of each
8. LABELS
The following label must be present and legible.
5
MSC06.1
052115