Installation Requirements; Power Supply; Grounding Connection - Frigidaire FARG4044MW Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION REQUIREMENTS

NOTE
Because of potentially inconsistent voltage capabilities, the use of this dryer with power created by gas powered
generators, solar powered generators, wind powered generators or any other generator other than the local utility
company is not recommended.
Electrical requirements for electric dryer
CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately
fused circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit.
POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current.
IMPORTANT
This dryer is internally grounded to neutral unless it was manufactured for sale in Canada.
Only a 4-conductor cord shall be used when the appliance is installed in a location where grounding through
the neutral conductor is prohibited. Grounding through the neutral link is prohibited for: (1) new branch circuit
installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes do not permit grounding
through the neutral.
OUTLET RECEPTACLE - NEMA 10-30R or NEMA 14-30R receptacle to be located so the power supply cord is accessible
when the dryer is in the installed position.
GROUNDING CONNECTION - See "Grounding requirements" in Electrical Installation section.
3-WIRE POWER SUPPLY CORD KIT (not supplied)
3-wire receptacle
(NEMA type 10-30R)
The dryer MUST employ a 3-conductor power
supply cord NEMA 10-30 type SRDT rated at 240
volt AC minimum, 30 amp, with 3 open end spade
lug connectors with upturned ends or closed
loop connectors and marked for use with clothes
dryers. For 3-wire cord connection instructions see
ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM.
4
4-WIRE POWER SUPPLY CORD KIT (not supplied)
4-wire receptacle
(NEMA type 14-30R)
The dryer MUST employ a 4-conductor power supply
cord NEMA 14-30 type SRDT or ST (as required) rated
at 240 volt AC minimum, 30 amp, with 4 open end
spade lug connectors with upturned ends or closed
loop connectors and marked for use with clothes
dryers. For 4-wire cord connection instructions see
ELECTRICAL CONNECTIONS FOR A 4-WIRE SYSTEM.
NOTE
Dryers manufactured for sale in Canada have factory-
installed, 4-wire power supply cord (NEMA 14-30R).

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Faqe7011lbFaqe7001lwFasg7074laFase7073lwFrqe7000lw

Tabla de contenido