DECLARATION OF CONFORMITY
This product is marked
– Low voltage no. 73/23 EEC and 93/68 EEC.
– Electromagnetic compatibility no. 89/336 ECC, 92/31 EEC
and 93/68 EEC.
This declaration will become void in case of of misusage
and/or non observance though partial of manu fa c t u r e r ' s
installation and/or operating instructions.
COOLING ONLY MODELS
OPERATING LIMITS
Maximum conditions
Outdoor temperature : 52°C D.B.*
Room temperature
Minimum conditions
Outdoor temperature : 19°C D.B.**
Room temperature
HEAT PUMP MODELS
OPERATING LIMITS
Cooling Maximum conditions
Outdoor temperature : 46°C D.B.
Room temperature
Cooling Minimum conditions
Outdoor temperature : 19°C D.B.
Room temperature
Heating Maximum conditions
Outdoor temperature : 24°C D.B. / 18°C W.B.
Room temperature
Heating Minimum conditions
Outdoor temperature : –8°C D.B. / –9°C W.B.
ACCESSORIES SUPPLIED WITH THE UNIT
PARTS
FIGURE
RAWL PLUG
PLASTIC
COVER
HEX
WRENCH
TAPPING
SCREW
*
Available only for heat pump models.
as it satisfies Directives:
: 35°C D.B. / 22.5°C W.B.
: 19°C D.B. / 14°C W.B.
: 35°C D.B. / 22°C W.B.
: 19°C D.B. / 14°C W.B.
: 27°C D.B.
Q.TY
PARTS
FIGURE
REMOTE
7
CONTROL UNIT
R E M OTE CONTRO L
1
UNIT SCREW
AAA ALKALINE
1
BATTERY
DRAIN
6
ELBOW
*
INSTALLATION INSTRUCTIONS
- Split system air conditioner -
Model Combinations
Combine indoor and outdoor units only as listed below.
Indoor Units
MA74C5
MA94C5
MA125C5
MA184C5
MA224C5
MA75R5
MA95R5
MA125R5
MA185R5
MA225R5
Power Supply:
The last digit(s) of the model number indicates the required
power supply to the unit.
5 : 220 - 240 V ~ 50 Hz / 7 : 380-400 V - 3N ~ 50 Hz
Tools required for installation (not supplied)
11. Standard screwdriver
12. Phillips head screwdriver
13. Knife or wire stripper
14. Tape measure
Q.TY
15. Level
16. Sabre saw or key hole saw
1
17. Hacksaw
18. Core bits ø 5
1
19. Hammer
10. Drill
11. Tube cutter
2
12. Tube flaring tool
13. Torque wrench
1
14. Adjustable wrench
15. Reamer (for reburring)
37.4163.125.1
06/97
COOLING ONLY MODELS
HEAT PUMP MODELS
Last digit(s) of the model number
10 11 305 F.GB.I.E.D.00
Outdoor Units
GR73C5
GR93C5
GR125C5
GR185C5
GR185C7
GR226C5
GR226C7
GR75R5
GR95R5
GR124R5
GR184R5
GR224R5