Manual Mode - Zenith Secure Home DualBrite SH-559 Manual Del Usaurio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Mode Switching Summary
TEST
AUTO

MANUAL MODE

* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
D
B
ual
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.
INSTALLATION
CAUTION: Keep the sensor at least 2" (51 mm)
away from the bulbs.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fixture to cool before touching. The bulb and
the fixture operate at high temperatures.
• Keep fixture at least 2" (51 mm) from combustible
materials. Do not aim at objects closer than 3' (1 m).
• Use only T4 100W (max.), G8 tungsten halogen
bi-pin 120 VAC bulbs.
For easy installation, select an existing light operated
by a wall switch for replacement.
NOT use with dimmers or timers.
For best performance, mount the fixture about 8 feet
(2.4 m) above the ground. NOTE: If fixture is mounted
higher than 8 feet (2.4 m), aiming the sensor down will
reduce coverage distance.
Move ON-TIME Switch to
1, 5, or 20 minutes
Flip light switch off
for one second then
back on*
Timer
®
rite
IMPORTANT:
Wall Mount
NOTE: Light fixture and sensor should be mounted as
shown above when installed (depending upon type of
installation).
Before installing the light fixture under an eave, the
sensor head must be rotated as shown in the next
two steps for proper operation and to avoid the risk of
electrical shock.
For eave mount only:
1. Swing the sensor head towards the clamp
screw joint.
Clamp Screw
2. Rotate the sensor head clockwise 180° so the
controls face down.
Do
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
2
Eave Mount
Controls
Controls
Controls
598-1162-04

Publicidad

Tabla de contenido
loading

Productos relacionados para Zenith Secure Home DualBrite SH-559

Tabla de contenido