CONTENTS
These parts are included with your DBI-600A blower:
2 - blower mounting legs*
1 - Parts Bag containing:
(4) wood screws #10 x .50*
(4) blower mount brackets
(1) strain relief bushing
(8) screws #10 x .38
(8) nuts #10
* For use when mounting DBI-600A blower directly to Down-
draft housing. (See Downdraft instruction manual.)
PLAN THE INSTALLATION
If you choose to mount the blower directly to the Downdraft
housing: Remove the inlet cover (taped in place for shipping)
and discard inlet cover. Refer to installation instructions in the
Downdraft manual.
If you choose to mount the blower in a remote location, (such
as the cabinet back, cabinet side, or floor joists) - follow the
instructions below.
INSTALL BLOWER
IN REMOTE LOCATION
NOTE: THE BLOWER MUST BE INSTALLED WITHIN 4-FEET OF
THE DOWNDRAFT'S ELECTRICAL PANEL. The Electrical Panel
can be mounted directly to the Downdraft housing - or mounted
in a remote location (always within 4-feet of the Flex Blower).
INLET
COVER
INLET
(from downdraft)
1. Position inlet cover over blower wheel. Securely attach the
inlet cover to the blower with 8 screws and 8 nuts from parts
bag. Note that inlet cover is taped to blower for shipping. This
tape may be removed.
2. Determine how the 8" round INLET and OUTLET ductwork
will connect to the blower.
BLOWER
OUTLET
(to roof cap
or wall cap)
3. Remove the necessary 1/4-20 x .50 hex head screws and
attach 4 MOUNTING BRACKETS to the blower - using 4 of
the 6 POSSIBLE BRACKET MOUNTING LOCATIONS.
8-IN.
ROUND
DUCT
(from
downdraft)
4. Mount blower to back of cabinet, floor joist, or adequate
framework (constructed by installer) with appropriate
MOUNTING SCREWS (not included).
5. Connect 8" ROUND DUCT from Downdraft housing to blower
inlet and from blower outlet to roof or wall cap.
For best performance: Choose the ducting option which allows
the shortest length of ductwork and a minimum number of
elbows and transitions. Check location of floor joists, wall
studs, electrical wiring or plumbing for possible interference.
6. Use strain relief bushing (provided) to attach blower wiring to
wiring box on Downdraft's electrical panel and make wiring
connections. (See Downdraft manual for instructions.)
Model DBI-600A
(4) MOUNTING
BRACKETS
attached with
1/4-20 X .50
HEX HEAD
SCREWS
(6) MOUNTING
BRACKET
LOCATIONS
MOUNTING SCREWS
(not included)
ROUND
DUCT
(to roof cap
or wall cap)
99046136 / 99045244
Page 2
8-IN.