Appendix A: Diagnostics Overview - Hart 5437 Manual Del Producto

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Incident Description
The device variable mapped to PV (and
analog out put current) is beyond its
operating limits.
Any other device variable is beyond its
operating limits.
The loop current has reached the
Current Output Upper Limit (UL) or
Output Lower Limit (LL) as configured
with command #147, and is no longer
corresponding to the PV value.
The analogue output current is being
simulated or disabled.
The configuration has changed since
this bit was last cleared (seen from
same master type, Primary- or
Secondary Master).
A sensor error (broken/shorted sensor)
is detected on Input 1
A sensor error (broken/shorted sensor)
is detected on Input 2.
This is only possible if Input type 2 is
<> "None"
A sensor error (broken/shorted sensor)
is detected on the CJC measurement
used for Input 1
A sensor error (broken/shorted sensor)
is detected on the CJC measurement
used for Input 2
The difference between measurements
on Input 1 and Input 2 is outside the
configured sensor drift limit
A sensor error (broken/shorted) is
detected on the primary sensor,
backup sensor is in use
A sensor error (broken/shorted) is
detected on the backup sensor,
primary sensor only is available
Configuration is temporarily invalid
< 3 seconds, e.g. while downloading
parameters
52

Appendix A: Diagnostics overview

Description
LED reaction
Primary Value Out
Flashing Red
Of Limits
Non-Primary Value
Flashing Red
Out Of Limits
Loop Current
Flashing Red
Saturated
Loop Current Fixed
Flashing Red
Configuration
No Impact
Changed
Primary Input 1
Flashing Red
error
Primary Input 2
Flashing Red
error
(only if Input 2 is
enabled)
CJC for Input 1 error
Flashing Red
(only if used)
CJC for Input 2 error
Flashing Red
(only if used)
Dual Input: Sensor
Flashing Red
drift alarm
(only if enabled)
Dual Input: Backup
No Impact
sensor OK, main
sensor error
Dual Input: Backup
No Impact
sensor error, main
sensor OK
Configuration not
Flashing Red
supported by device
5437V103-ES
Analog Output
NE-107 Class
Reaction
Enters configured
Maintenance
Value
required
No impact
Maintenance
required
Enters configured
If output range
Value
check is enabled:
Failure
otherwise
Maintenance
required
Enters configured
Function check
Value
No impact
N.A.
Enters configured
If no backup
Value
input is available
and mapped to
PV, then failure
otherwise
maintenance
required.
Enters configured
If no backup
Value
input is available
and mapped to
PV, then failure
otherwise
maintenance
required.
Enters configured
If no backup
Value
input is available
and mapped to
PV, then failure
otherwise
maintenance
required.
Enters configured
If no backup
Value
input is available
and mapped to
PV, then failure
otherwise
maintenance
required.
Enters configured
if sensor drift =
Value
error => failure
otherwise
maintenance
required.
No impact
Maintenance
required
No impact
Maintenance
required
Value is held
Failure
(freeze)
User action
Reconnect or repair sensor
Reconnect or repair sensor
Reconnect or repair sensor
N.A.
N.A.
Reconnect or repair sensor
Reconnect or repair sensor
Reconnect or repair sensor
Reconnect or repair sensor
Reconnect or repair sensor
Reconnect or repair sensor
Reconnect or repair sensor
N.A.
Error
#
0
1
2
3
6
10
11
12
13
14
15
16
17

Publicidad

Tabla de contenido
loading

Productos relacionados para Hart 5437

Tabla de contenido